首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
废物处理   4篇
环保管理   1篇
综合类   1篇
污染及防治   1篇
  2014年   1篇
  2013年   1篇
  2012年   1篇
  2011年   2篇
  2008年   1篇
  2007年   1篇
排序方式: 共有7条查询结果,搜索用时 15 毫秒
1
1.
Nitrogen evolution was studied during the co-combustion of hydrothermally treated municipal solid wastes (HT MSW) and coal in a bubbling fluidized bed (BFB). HT MSW blending ratios as 10%, 20% and 30% (wt.%) were selected and tested at 700, 800, 900 °C. Emissions of NO and N2O from blends were measured and compared with the results of mono-combustion trials. Moreover, concentrations of precursors like NH3 and HCN were also quantified. The results are summarized as follows: NO emissions were predominant in all the cases, which rose with increasing temperature. The blending of HT MSW contributed to the NO reduction. N2O emissions decreased with temperature rising and the blending of HT MSW also presented positive effects. At 30% HT MSW addition, both NO and N2O emissions showed the lowest values (391.85 ppm and 55.33 ppm, respectively at 900 °C). For the precursors, more HCN was detected than NH3 and both played important roles on the gas side nitrogen evolution.  相似文献   
2.
Otero M  Gómez X  García AI  Morán A 《Chemosphere》2007,69(11):1740-1750
Combustion of urban sewage sludge together with coal in existing infrastructures may be a sustainable management option energetically interesting for these materials, usually considered wastes. Thermogravimetric analysis was used to study the combustion of a semianthracite coal and the modifications undergone when adding a small percentage (2%, 5%, 10%) of sewage sludge. Both Differential Scanning Calorimetric analysis and Differential Thermogravimetry burning profiles showed differences between coal and sewage sludge combustion. However, the effects of adding a percentage of sewage sludge equal or smaller than 10% was hardly noticeable in terms of heat release and weight loss during the coal combustion. This was further proved by non-isothermal kinetic analysis, which was used to evaluate the Arrhenius activation energy corresponding to the co-combustion of the blends. This work shows that thermogravimetric analysis may be used as an easy rapid tool to asses the co-combustion of sewage sludge together with coal.  相似文献   
3.
Co-combustion of dried sewage sludge and coal in a pulverized coal boiler   总被引:1,自引:0,他引:1  
More than 1.1 million tons of municipal and industrial sewage sludge is produced annually in Poland. Most of this sewage sludge is landfilled or used for recultivation and fertilization of soil. After accession of Poland to the EU, large investments are planned for wastewater treatment, so it is expected that the amount of sewage sludge produced in Poland will grow in the near future. It is well known that the combustion of sewage sludge is becoming a more and more popular utilization method of such waste. Unfortunately, the current situation in Poland makes it impossible to incinerate the sewage sludge because of a lack of incinerators. One possible solution for Poland is the co-firing of dried sewage sludge in existing coal-fired utility boilers. This article presents results of initial Polish industrial trials of dried municipal sewage sludge and hard coal co-combustion in an OP-230 pulverized coal boiler. Such a solution was shown to be technically viable and not to require changes to the existing technological system. Cocombustion of sewage sludge with coal in power plants seems to be the best solution for sludge utilization in the near future in Poland.  相似文献   
4.
Three alternative condensing mode power and combined heat and power (CHP) waste-to-energy concepts were compared in terms of their impacts on the greenhouse gas (GHG) emissions from a heat and power generation system. The concepts included (i) grate, (ii) bubbling fluidised bed (BFB) and (iii) circulating fluidised bed (CFB) combustion of waste. The BFB and CFB take advantage of advanced combustion technology which enabled them to reach electric efficiency up to 35% and 41% in condensing mode, respectively, whereas 28% (based on the lower heating value) was applied for the grate fired unit. A simple energy system model was applied in calculating the GHG emissions in different scenarios where coal or natural gas was substituted in power generation and mix of fuel oil and natural gas in heat generation by waste combustion. Landfilling and waste transportation were not considered in the model. GHG emissions were reduced significantly in all of the considered scenarios where the waste combustion concepts substituted coal based power generation. With the exception of condensing mode grate incinerator the different waste combustion scenarios resulted approximately in 1 Mton of fossil CO2-eq. emission reduction per 1 Mton of municipal solid waste (MSW) incinerated. When natural gas based power generation was substituted by electricity from the waste combustion significant GHG emission reductions were not achieved.  相似文献   
5.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are formed during waste incineration and in waste-to-energy boilers. Incomplete combustion, too short residence times at low combustion temperatures (<700 °C), incineration of electronic waste and plastic waste containing chlorine are all factors influencing the formation of PCDD/Fs in boilers. The impact of chlorine and catalysing metals (such as copper and iron) in the fuel on PCDD/F formation was studied in a 12 MWth circulating fluidised bed (CFB) boiler. The PCDD/F concentrations in the raw gas after the convection pass of the boiler and in the fly ashes were compared. The fuel types were a so-called clean biomass with low content of chlorine, biomass with enhanced content of chlorine from supply of PVC, and solid recovered fuel (SRF) which is a waste fuel containing higher concentrations of both chlorine, and catalysing metals. The PCDD/F formation increased for the biomass with enhanced chlorine content and it was significantly reduced in the raw gas as well as in the fly ashes by injection of ammonium sulphate. A link, the alkali chloride track, is demonstrated between the level of alkali chlorides in the gas phase, the chlorine content in the deposits in the convection pass and finally the PCDD/F formation. The formation of PCDD/Fs was also significantly reduced during co-combustion of SRF with municipal sewage sludge (MSS) compared to when SRF was fired without MSS as additional fuel.  相似文献   
6.
Under the framework of the European project named COPOWER, the possibility to partially substitute coal used in a 243 MWth Power Plant by biomass and non-hazardous wastes for the production of electricity and steam was assessed. Three combustion scenarios were studied, based on the combustion tests performed in a Power Plant located in Duisburg (Germany): Scenario 0 (Sc0) - combustion of coal; Scenario 1 (Sc1) - combustion of coal + sewage sludge (SS) + meat and bone meal (MBM); Scenario 2 (Sc2) - coal + SS + wood pellets (WP). An environmental and socio-economic assessment of these three scenarios was performed. In the environmental point of view, Sc0 was the worst scenario, mainly due to the emission of greenhouse gases (GHG). Sc1 was the best scenario, mainly due to the reduction of GHG emission, eutrophication chemical species and ozone depletion gases. In the socio-economic point of view, Sc0 was the worst scenario, mainly due to the absence of GHG abatement, and Sc1 was the best scenario due to the best cost of electricity production and negative cost of avoided emissions.  相似文献   
7.
Recovering energy from wastes is a useful strategy for integrated waste and energy management in an eco-industrial park (EIP) and gives promising reduction of wastes, total energy consumption and operation cost. In Jinqiao EIP, Pudong New Area, Shanghai, an industrial symbiosis, based on the energy recovery from municipal sewage sludge and re-refined oil, was proposed in the central heat-supplying company of Jinqiao EIP. It is expected that hot off-gas or part of the steam from the central heat-supplying company could be used for sludge drying and used oil re-refining while the dried sludge and refined oil can be partial substitution for fossil fuel. For the purpose of assessing the environmental performance of this industrial symbiosis, life cycle assessment (LCA) was used and different scenarios were set up in this study to evaluate the Global warming Potential (GWP), Acidification Potential (AP), Eutrophication Potential (EP), Human toxicity air (HTA) and Total Environmental Impact Potential (TEIP) of the system. Results indicate that when the substitute ratio of coal by sludge is 14%, the proposed industrial symbiosis has the least environmental impact. Compared with the current situation (sludge is landfilled), co-combustion of dried sludge and re-refined oil with coal at optimal scale will release less CO2, CH4, NOx, N2O and CO, but more SO2, H2S, NH3, HCl, polycyclic aromatic hydrocarbons (PAHs), non-methane volatile organic compounds (NMVOC) and heavy metals.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号