排序方式: 共有37条查询结果,搜索用时 328 毫秒
1.
2.
对铜的 3条谱线 (2 49.2 nm、2 61 .4nm,3 2 4.8nm ) ,铅的 2条谱线 (2 83 .3 nm、2 1 7.0 1 nm )以及锌的 2条谱线(3 0 7.6nm、2 1 3 .9nm ) ,共 7条谱线的灵敏度、检测限、线性范围进行了归纳性总结 ,并对多种共存元素可能存在的干扰情况进行了研究 ,认为利用元素不同分析谱线的分析灵敏度差异 ,根据被测元素在样品消解液中含量 ,选择合适的谱线进行分析 ,既降低工作强度 ,又能获得满意结果 相似文献
3.
4.
A new method that utilizes pretreated silica gel as an adsorbent has been developed for simultaneous preconcentration of trace Cd(II) and Pb(II) prior to the measurement by flame atomic absorption spectrometry. The effects of pH, the shaking time, the elution condition and the coexisting ions on the separation/preconcentration conditions of analytes were investigated. Under optimized conditions, the static adsorption capacity of Cd(II) and Pb(II) were 45.5 and 27.1mg/g, the relative standard deviations were 3.2% and 1.7% (for n = 11), and the limits of detection obtained were 4.25 and 0.60 ng/mL, respectively. The method was validated by analyzing the certified reference materials GBW 07304a (stream sediment) and successfully applied to the analysis of various treated wastewater samples with satisfactory results. 相似文献
5.
对采用原子吸收火焰法次灵敏线测定污水和电镀污泥中高含量的锌进行了研究。试验结果表明:在锌浓度50.0~600.0mg/L之间,溶液锌含量与吸光度呈线性关系。线性回归方程为y=0.000661x-0.0007,相关系数γ=0.9998。方法检出限为25.0mg/L,相对标准误差(RSD)<2.96%,加标回收率为92.5%~105%,与标准法的相对误差<2.76%。 相似文献
6.
Penicillium chrysogenum was immobilized on silica to develop a simple and cost effective method for solid phase extraction of Cd(II) and determination using flame atomic absorption spectrometry (FAAS). The sorbent was characterized by Fourier transform infrared spectroscopy and packed into a column. The conditions for quantitative sorption and desorption of Cd(II) were optimized. The preconcentration factor was 100 while detection limit was 0.61 µg L?1 with a relative standard deviation of 1.0%. The method was applied for determination of Cd in herbal medicine and tap water. 相似文献
7.
8.
9.
研究提出了用磷酸钕(NdPO4)作为共沉淀捕集剂分离富集环境水样中的痕量Pb2 ,用火焰原子吸收光谱(FAAS)测定的方法.共沉淀受pH、NdCl3和H3PO4溶液用量的影响.结果显示,在溶液pH为3.2时,20 mL水样中加入5 mg/L NdCl3 2 mL、0.5 mol/L H3PO4 3 mL条件下,铅的加标回收率为96.6%~104.2%,方法的检测限为5.7×10-3 mg/L,水体中常见碱金属、碱土金属离子及阴离子在一定范围内不影响测定. 相似文献
10.
A facile and novel method has been developed for the determination of cadmium, chromium, copper, lead, and zinc from various water samples using FAAS. In the present investigation, a syringe was loaded with sorbent (rice bran) for the separation and enrichment of cadmium, chromium, copper, lead, and zinc, prior to their analysis by flame atomic absorption spectrometry which was described to substitute the batch and column techniques. The syringe was loaded with 2.0 g of sorbent in order to retain the analyte elements. Six milliliter of sample solution (pH 8.0 ± 0.2) was drawn into the syringe in 15 s and discharged over a period of 15 s. Then, 2.0 M HCl eluent was drawn into the syringe and ejected back to desorb the analyte elements. At the optimum conditions, the percentage recoveries of Cd, Cr, Cu, Pb, and Zn was in the range of 95.5–99.4% with SD of 0.10%. The elements could be concentrated by drawing and discharging several portions of sample successively. The detailed study of various interferences made the confirmation of the method highly selective. The risk of contamination is less than that with the column technique. The method was successfully applied for the determination of Cd, Cr, Cu, Pb, and Zn in spiked and natural water samples. The results obtained are in good agreement with the reported methods at the 95% confidence level. 相似文献