排序方式: 共有24条查询结果,搜索用时 31 毫秒
1.
The degradation of plastic debris may result in the generation of nanoplastics (NPs). Their high specific surface area for the sorption of organic pollutions and toxic heavy metals and possible transfer between organisms at different nutrient levels make the study of NPs an urgent priority. However, there is very limited understanding on the occurrence, distribution, abundant, and fate of NPs in the environment, partially due to the lack of suitable techniques for the separation and identification of NPs from complex environmental matrices. In this review, we first overviewed the state-of-the-art methods for the extraction, separation, identification and quantification of NPs in the environment. Some of them have been successfully applied for the field determination of NPs, while some are borrowed from the detection of microplastics or engineered nanomaterials. Then the possible fate and transport of NPs in the environment are thoroughly described. Although great efforts have been made during the recent years, large knowledge gaps still exist, such as the relatively high detection limit of existing method failing to detect ultralow masses of NPs in the environment, and spherical polystyrene NP models failing to represent the various compositions of NPs with different irregular shapes, which needs further investigation. 相似文献
2.
3.
南方涝渍地区退田还渔的一个实例分析 总被引:2,自引:0,他引:2
以江汉平原四湖涝渍地区的一个经围湖造田形成的典型农业微域为研究对象,在对其土壤和作物生长状况进行调查的基础上,探讨了退田还渔的必要性与具体方案。结果表明,对小型湖泊通过围湖造田所形成的农业微域,在人工排水和土地平整不充分的情况下,其地貌和土壤还残留有原有湖泊的影响,处于原湖泊低处的土壤表现出明显的沼泽化和严重潜育化的特征。在该地区种植水稻产量比正常地区减产达16%~26.8%。利用数量化理论Ⅰ确定了该地区适宜退田还渔的具体位置和面积。按照这一方案实施的结果,该地区从1997~2001年的5年中精养鱼塘面积增加9倍,养鱼的效益比种植水稻高5~10倍,还减轻了该地区夏季和冬季的排水压力。 相似文献
4.
事故树定量分析与安全指标的数学模型的建立 总被引:4,自引:3,他引:4
阐述了在该课题研究过程中,提出的一些新概念、新定义和新方法 相似文献
5.
One methodology is proposed to estimate the quantification and composition of building-related construction and demolition (C&D) waste in a fast developing region like Shanghai, PR China. The varieties of structure types and building waste intensities due to the requirement of progressive building design and structure codes in different decades are considered in this regional C&D waste estimation study. It is concluded that approximately 13.71 million tons of C&D waste was generated in 2012 in Shanghai, of which more than 80% of this C&D waste was concrete, bricks and blocks. Analysis from this study can be applied to facilitate C&D waste governors and researchers the duty of formulating precise policies and specifications. As a matter of fact, at least a half of the enormous amount of C&D waste could be recycled if implementing proper recycling technologies and measures. The appropriate managements would be economically and environmentally beneficial to Shanghai where the per capita per year output of C&D waste has been as high as 842 kg in 2010. 相似文献
6.
红外光谱法测定粉尘中游离二氧化硅综述 总被引:1,自引:1,他引:0
全面地回顾了国内外红外光谱法测定粉尘中游离二氧化硅的研究成果。系统而重点地介绍了溴化钾压片法、粉尘滤膜样品重沉积和采样滤膜直接测定技术,分析了样品粒度、标准石英物质和矿物干扰物对测定结果的影响及干扰消除方法;还介绍了国外对红外光谱法与X-射线衍射法进行比较性研究的结果和动态,并得出结论。文章所列参考文献对本领域研究人员和基层检测人员具有很高的参考价值。 相似文献
7.
8.
《环境科学学报(英文版)》2023,35(4):784-793
Despite millions of seafarers and passengers staying on ships each year, few studies have been conducted on the indoor air quality inside ship hulls. In this study, we investigated the levels and size distribution of indoor particulate matter during two cruises of the research vessel “Xuelong” from Shanghai to Antarctica. The results showed that the particle size less than 2.5 µm (PM2.5), and particle size less than 10 µm (PM10) concentrations in different rooms of the ship widely varied. We observed high particulate matter (PM) levels in some of the rooms. The mass concentration distribution was dominated by 1–4 µm particles, which may have been caused by the hygroscopic growth of fine particles. The dominant factors influencing PM concentrations were indoor temperature, relative humidity, and human activity. We quantified contributions of these factors to the levels of indoor particles using a generalized additive model. In clean rooms, the levels of indoor particles were controlled by temperature and relative humidity, whereas in polluted rooms, the levels of indoor particles were mainly influenced by temperature and human activity, which implied that controlling temperature and human activity would efficiently reduce the levels of indoor particles. 相似文献
9.
Rahel C. Brändli Upal Ghosh Gijs D. Breedveld Gerard Cornelissen 《Environmental pollution (Barking, Essex : 1987)》2009,157(12):3465-3470
Activated carbon (AC) strongly sorbs organic pollutants and can be used for remediation of soils and sediments. A method for AC quantification is essential to monitor AC (re)distribution. Since AC is black carbon (BC), two methods for BC quantification were tested for AC mixed in different soils and sediments: i) chemothermal oxidation (CTO) at a range of temperatures and ii) wet-chemical oxidation with a potassium dichromate/sulfuric acid solution. For three soils, the amount of AC was accurately determined by CTO at 375 °C. For two sediments, however, much of the AC disappeared during combustion at 375 °C, which could probably be explained by catalytic effects by sediment constituents. CTO at lower temperatures (325-350 °C) was a feasible alternative for one of the sediments. Wet oxidation effectively functioned for AC quantification in sediments, with almost complete AC recovery (81-92%) and low remaining amounts of native organic carbon (5-16%). 相似文献
10.
N. González Pericot P. Villoria Sáez M. Del Río Merino O. Liébana Carrasco 《Waste management (New York, N.Y.)》2014,34(11):1932-1938
The construction sector is responsible for around 28% of the total waste volume generated in Europe, which exceeds the amount of household waste. This has led to an increase of different research studies focusing on construction waste quantification. However, within the research studies made, packaging waste has been analyzed to a limited extent. This article focuses on the packaging waste stream generated in the construction sector. To this purpose current on-site waste packaging management has been assessed by monitoring ten Mediterranean residential building works. The findings of the experimental data collection revealed that the incentive measures implemented by the construction company to improve on-site waste sorting failed to achieve the intended purpose, showing low segregation ratios. Subsequently, through an analytical study the generation patterns for packaging waste are established, leading to the identification of the prevailing kinds of packaging and the products responsible for their generation. Results indicate that plastic waste generation maintains a constant trend throughout the whole construction process, while cardboard becomes predominant towards the end of the construction works with switches and sockets from the electricity stage. Understanding the production patterns of packaging waste will be beneficial for adapting waste management strategies to the identified patterns for the specific nature of packaging waste within the context of construction worksites. 相似文献