首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Methyl tert-butyl ether (MTBE) in finished drinking water in Germany
Authors:Kolb Axel  Püttmann Wilhelm
Institution:Johann Wolfgang Goethe-University Frankfurt am Main, Institute of Mineralogy, Department of Analytical Environmental Chemistry, Georg-Voigt-Str. 14, D-60054 Frankfurt am Main, Germany. a.kolb@kristall.uni-franfurt.de
Abstract:In the present study 83 finished drinking water samples from 50 cities in Germany were analyzed for methyl tert-butyl ether (MTBE) content with a detection limit of 10 ng/L. The detection frequency was 46% and the concentrations ranged between 17 and 712 ng/L. Highest concentrations were found in the community water systems (CWSs) of Leuna and Spergau in Saxony-Anhalt. These CWSs are supplied with water possibly affected by MTBE contaminated groundwater. MTBE was detected at concentrations lower than 100 ng/L in drinking water supplied by CWSs using bank filtered water from Rhine and Main Rivers. The results from Leuna and Spergau show that large groundwater contaminations in the vicinity of CWSs pose the highest risk for MTBE contamination in drinking water. CWSs using bank filtered water from Rhine and Main Rivers are susceptible to low MTBE contaminations in finished drinking water. All measured MTBE concentrations were below proposed limit values for drinking water.
Keywords:
本文献已被 PubMed 等数据库收录!