首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Application of constructed wetlands for wastewater treatment in tropical and subtropical regions (2000-2013)
Authors:Dong-Qing Zhang  KBSN Jinadas  Richard M Gersberg  Yu Liu  Soon Keat Tan and Wun Jern Ng
Institution:1. Advanced Environmental Biotechnology Centre, Nanyang Environment & Water Research Institute, Nanyang Technological University,1 CleanTech Loop, #06-10, 637141, Singapore
2. Department of Civil Engineering, University of Peradeniya, Peradeniya 20400, Sri Lanka
3. Graduate School of Public Health, San Diego State University, Hardy Tower 119, 5500 Campanile, San Diego, CA 92182-4162, USA
Abstract:Constructed wetlands (CWs) have been successfully used for treating various wastewaters for decades and have been identified as a sustainable wastewater management option for developing countries. With the goal of promoting sustainable engineered systems that support human well-being but are also compatible with sustaining natural (environmental) systems, the application of CWs has become more relevant. Such application is especially significant for developing countries with tropical climates, which are very conducive to higher biological activity and productivity, resulting in higher treatment efficiencies compared to those in temperate climates. This paper therefore highlights the practice, applications, and research of treatment wetlands under tropical and subtropical conditions since 2000. In the present review, removal of biochemical oxygen demand (BOD) and total suspended solid (TSS) was shown to be very efficient and consistent across all types of treatment wetlands. Hybrid systems appeared more efficient in the removal of total suspended solid (TSS) (91.3%), chemical oxygen demand (COD) (84.3%), and nitrogen (i.e., 80.7% for ammonium (NH)4-N, 80.8% for nitrate (NO)3-N, and 75.4% for total nitrogen (TN)) as compared to other wetland systems. Vertical subsurface flow (VSSF) CWs removed TSS (84.9%), BOD (87.6%), and nitrogen (i.e., 66.2% for NH4-N, 73.3% for NO3-N, and 53.3% for TN) more efficiently than horizontal subsurface flow (HSSF) CWs, while HSSF CWs (69.8%) showed better total phosphorus (TP) removal compared to VSSF CWs (60.1%). Floating treatment wetlands (FTWs) showed comparable removal efficiencies for BOD (70.7%), NH4-N (63.6%), and TP (44.8%) to free water surface (FWS) CW systems.
Keywords:Constructed wetlands  Treatment  Nutrient  Removal  Tropical
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《环境科学学报(英文版)》浏览原始摘要信息
点击此处可从《环境科学学报(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号