Reuse rate of treated wastewater in water reuse system |
| |
Authors: | FAN Yao-bo YANG Wen-bo LI Gang WU Lin-lin and WEI Yuan-song |
| |
Institution: | Department of Water Pollution Control Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China |
| |
Abstract: | A water quality model for water reuse was made by mathematics induction. The relationship among the reuse rate of treated wastewater(R), pollutant concentration of reused water(C_s), pollutant concentration of influent(C_0), removal efficiency of pollutant in wastewater(E), and the standard of reuse water were discussed in this study. According to the experiment result of a toilet wastewater treatment and reuse with membrane bioreactors, R would be set at less than 40%, on which all the concerned parameters could meet with the reuse water standards. To raise R of reuse water in the toilet, an important way was to improve color removal of the wastewater. |
| |
Keywords: | water quality model reuse rate wastewater treatment water reuse |
本文献已被 CNKI 维普 万方数据 PubMed 等数据库收录! |
| 点击此处可从《环境科学学报(英文版)》浏览原始摘要信息 |
| 点击此处可从《环境科学学报(英文版)》下载免费的PDF全文 |