Authors:Kai-Chung Cheng  Marian D Goebes  Lynn M Hildemann
Institution:1. School of Public Health, University of Alberta, 3-57 South Academic Building, 11405-87 Avenue, Edmonton, Alberta T6G 1C9, Canada;2. Health Canada, 269 Laurier Avenue West, Ottawa, Ontario K1A 0K9, Canada;3. Consultant, 428 Woodley Way, Santa Rosa, California 95409, United States
Abstract:The effect of foot traffic on indoor particle resuspension was evaluated by associating non-prescribed foot traffic with simultaneous size-resolved airborne particulate matter (PM) concentrations in a northern California hospital. Foot traffic and PM were measured every 15 min in a carpeted hallway over two 27-h periods. The PM concentration in the hallway was modeled based on the foot traffic intensity, including the previous PM concentration via an autocorrelation regression method based on the well-mixed box model. All 5 size ranges of PM, ranging from 0.75–1 μm to 5–7.5 μm, were highly correlated with foot traffic measurements for both monitoring periods (p < 0.001, R2 = 0.87–0.90). However, correlations during daytime hours were less significant than nighttime. Coefficients found via this autoregressive analysis can be interpreted to reveal (i) time-independent contributions of walking activities on PM levels for a specific location; and (ii) size-specific characteristics of the resuspended PM.