首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Development of a variable configuration cascade impactor for aerosol size distribution measurement
Authors:Sanjay Singh  BK Sapra  Arshad Khan  PK Kothalkar  YS Mayya
Institution:1. Tampere University of Technology, Department of Physics, Aerosol Physics Laboratory, P.O. Box 692, FI-33101 Tampere, Finland;2. Metropolia University of Applied Sciences, Department of Technology, P.O. Box 4021, FIN-00180 Helsinki, Finland;1. Xi’an Jiaotong Univ, Sch Energy & Power Engn, Xi’an 710049, PR China;2. State Key Laboratory of Power System of Tractor, PR China;3. Luoyang Tractor Research Institute Co., Ltd, PR China;1. Respiratory Technology, Woolcock Institute of Medical Research, The University of Sydney, NSW 2037, Sydney, Australia;2. Discipline of Pharmacology, Sydney Medical School, University of Sydney, NSW 2000, Australia;3. Department of Chemical and Pharmaceutical Sciences, University of Ferrara, Ferrara, Italy
Abstract:In atmospheric aerosol studies, it is often required to use two different impactors, namely, the normal pressure and the low-pressure impactor, to measure the mass-size distribution over a wide size range. From the perspective of rendering the system compact for such measurements, it may be more advantageous to combine the two features in a single instrument. In an effort towards exploring this option, a variable configuration cascade impactor (VCCI) comprising of 7 normal pressure and 4 low-pressure stages has been designed and developed. In configuration-1, it operates as a low-pressure impactor, with a sampling flow rate of 10 L min?1 and classifies the particles from 0.1 to 21 μm in eleven size classes. In configuration-2, it operates as a normal pressure impactor, with a sampling flow rate of 45 L min?1, and classifies the particles from 0.53 to 10 μm in seven size classes. As part of performance evaluation of the system, the deposit patterns and the integral performance have been studied. For integral performance, a comparative mass-size distribution measurement between VCCI and standard Andersen impactor was carried out. Its performance was also evaluated against the GRIMM Scanning Mobility Particle Sizer (SMPS) in the common size range of both these instruments and against GRIMM Optical Particle Counter (OPC). In addition to this, VCCI was evaluated for its performance in the PMx configuration obtained by removing a few of the impactor stages sequentially and measuring corresponding size distribution for every stage removed. Changes in the distribution parameters due to spillover of the deposits of previous stage to remaining stages were within 10%. This variation is well within the generally accepted value for all environmental measurement related applications.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号