Measurement of air exchange rates in different indoor environments using continuous CO2 sensors |
| |
Authors: | Yan You Can Niu Jian Zhou Yating Liu Zhipeng Bai Jiefeng Zhang Fei He Nan Zhang |
| |
Affiliation: | State Environmental Protection Key Laboratory of Urban Ambient Air Particulate Matter Pollution Prevention and Control, College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071, China;Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.;State Environmental Protection Key Laboratory of Urban Ambient Air Particulate Matter Pollution Prevention and Control, College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071, China;State Environmental Protection Key Laboratory of Urban Ambient Air Particulate Matter Pollution Prevention and Control, College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071, China;State Environmental Protection Key Laboratory of Urban Ambient Air Particulate Matter Pollution Prevention and Control, College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071, China;State Environmental Protection Key Laboratory of Urban Ambient Air Particulate Matter Pollution Prevention and Control, College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071, China;State Environmental Protection Key Laboratory of Urban Ambient Air Particulate Matter Pollution Prevention and Control, College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071, China;State Environmental Protection Key Laboratory of Urban Ambient Air Particulate Matter Pollution Prevention and Control, College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071, China;State Environmental Protection Key Laboratory of Urban Ambient Air Particulate Matter Pollution Prevention and Control, College of Environmental Sciences and Engineering, Nankai University, Tianjin 300071, China |
| |
Abstract: | A new air exchange rate (AER) monitoring method using continuous CO2 sensors was developed and validated through both laboratory experiments and field studies. Controlled laboratory simulation tests were conducted in a 1-m3 environmental chamber at different AERs (0.1-10.0 hr-1). AERs were determined using the decay method based on box model assumptions. Field tests were conducted in classrooms, dormitories, meeting rooms and apartments during 2-5 weekdays using CO2 sensors coupled with data loggers. Indoor temperature, relative humidity (RH), and CO2 concentrations were continuously monitored while outdoor parameters combined with on-site climate conditions were recorded. Statistical results indicated that good laboratory performance was achieved: duplicate precision was within 10%, and the measured AERs were 90%-120% of the real AERs. Average AERs were 1.22, 1.37, 1.10, 1.91 and 0.73 hr-1 in dormitories, air-conditioned classrooms, classrooms with an air circulation cooling system, reading rooms, and meeting rooms, respectively. In an elderly particulate matter exposure study, all the homes had AER values ranging from 0.29 to 3.46 hr??1 in fall, and 0.12 to 1.39 hr-1 in winter with a median AER of 1.15. |
| |
Keywords: | air exchange rate continuous CO2 sensor steady-state method decay method particulate matter indoor-outdoor concentration relationship |
本文献已被 ScienceDirect PubMed 等数据库收录! |
| 点击此处可从《环境科学学报(英文版)》浏览原始摘要信息 |
|
点击此处可从《环境科学学报(英文版)》下载全文 |
|