摘    要:介绍了用高流量大气采样器和瓦特曼滤膜采集样品,以硝酸-高氯酸消化,无火焰原子吸收分光光度法测定海洋气溶胶中铜、铅、镉。对高流量大气采样流量校准、滤膜选用,仪器测试条件及消化方法进行试验和讨论。本方法检测限分别为铜1.8ng/m3、铅1.4ng/m3、镉0.7ng/m3,变异系数分别为铜9.6%、铅8.9%、镉18.0%。

关 键 词:海洋气溶胶        测定  分光光度法

Determination of Cu,Pb,Cd in Marine Aerosol by AAS
Li lianke, Li Jun, Gao Guangzhi.Determination of Cu,Pb,Cd in Marine Aerosol by AAS[J].Chongqing Environmental Science,1996,18(5):56-61.
Authors:Li lianke  Li Jun  Gao Guangzhi
Abstract:A determination method of copper ,lead and cadmium in the marine aerosol by AAS,saniples using a large volume atmospheric sampler and through Wahtman 41 # filter and digestion method with nitricerchloric acid were presented. Volume correction, various filters,AAS measurement and the digestion methods were compared and discussed. The detection limits for copper, lead and cadrnium were 1.8ng/m3,1.4ng/m3 and 0. 7ng/m3 respectively.The coefficients of variation for copper, lead and cadmium were 9. 6%,8. 9% and 1.8% respectively.
Keywords:Marine aerosol  Determination of copper  lead and cadmium  AAS  