摘    要:广东粤电油页岩发电项目2×210MW机组CFB锅炉燃用茂名本地油页岩,除尘设备在可研和初步设计时均选用双室5电场高效静电除尘器,在烟气脱硫工程招标文件审查时发现脱硫装置入口烟尘浓度偏高,不能满足烟气脱硫装置要求,故重新对除尘器进行了调研、分析、选型。

关 键 词:除尘器  分析  选型

ESP type selection of 2 ×210 MW units in oil shale electricity generation project
CHEN Ru-huang,ZHONG Wei-hong.ESP type selection of 2 ×210 MW units in oil shale electricity generation project[J].Electric Power Environmental Protection,2009,25(4):58-60.
Authors:CHEN Ru-huang  ZHONG Wei-hong
Abstract:The ESP equipment type selection of the CFB boiler of 2 × 210 MW units in the Guangdong oil shale electricity generation project which burned Maoming local oil shale were discussed. The double - room five electric field high dust removing electrostatic precipitator(ESP) was selected in preliminary design. It was discovered that the FGD installment entrance mist and dust density were higher than the standard and could not satisfy the flue gas desulfurization system request when the desulfurization project tender document were examined. The EPS type selections were invested and analyzed once more.