首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Reducing Interference Effects in the Chemiluminescent Measurement of Nitric Oxides from Combustion Systems
Authors:Robert J Tidona  Ahtisham A Nizami  Nicholas P Cernansky
Institution:Drexel University , Philadelphia , Pennsylvania , USA
Abstract:Experiments were carried out to determine the relative chemiluminescence quenching efficiencies as a function of third body concentration for each of the common combustion products, H2O, CO2, CO, H2, O2 and Ar. These results are compared with those of other investigators. The effect of reaction chamber pressure on analyzer response and the development of an analyzer design which incorporates an adjustable sample capillary inlet capable of maintaining a constant molar flow rate of sample gas to the reaction chamber are discussed. The effect of carbon monoxide interference on chemiluminescent NOx measurement has been isolated and found to be significant. A means of correcting NO, measurements for these CO interference effects is described. Quantification of NO and NO2 absorption in liquid water in NOx sampling systems has been made. Recommendations for sample system designs to handle the presence of water in the sample gas are made.