首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Particulate and Nicotine Sampling in Public Facilities and Offices
Authors:Elizabeth A Miesner  Stephen N Rudnick  Fu-Chang Hu  John D Spengler  Liesbeth Preller  Halûk Özkaynak
Institution:1. Harvard School of Public Health , Boston , Massachusetts , USA;2. Wageningen Agricultural University , Wageningen , The Netherlands;3. Harvard University , Cambridge , Massachusetts , USA
Abstract:Abstract

The purpose of this study was to characterize and measure indoor air quality in public facilities and office buildings. The pollutants of interest were particulate matter smaller than 2.5 μm in diameter, PM-2.5, and environmental tobacco smoke (ETS). Integrated PM- 2.5 samples were taken on Teflon membrane filters using Harvard Aerosol Impactors as a pre-size selector. Filters were analyzed by gravimetric analysis. Nicotine, which was used as a marker for ETS, was collected on sodium-bisulfate-impregnated, glass-fiber filters and was analyzed by gas chromatography. Twenty-one structures were monitored in Metropolitan Boston. Measured particle concentrations ranged from 6.0 μg/m3 to about 550 μg/m3. Nicotine concentrations were as high as 26 μg/m3 in a designated smoking room. Real-time measurements were also taken using two types of nephelometers; a Handheld Aerosol Monitor (HAM) and a Miniature Real-Time Aerosol Monitor (MINIRAM). Short-term field measurements with these instruments correlated better with the integrated PM-2.5 concentrations in smoking locations than with concentrations in non-smoking areas.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏