首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于2D-COS分析的难凝聚有机物臭氧化特性研究
引用本文:金鑫,侯瑞,宋吉娜,金鹏康,王晓昌.基于2D-COS分析的难凝聚有机物臭氧化特性研究[J].中国环境科学,2018,38(3):923-928.
作者姓名:金鑫  侯瑞  宋吉娜  金鹏康  王晓昌
作者单位:1. 西安建筑科技大学环境与市政工程学院, 陕西 西安 710055;2. 河北工程大学能源与环境学院, 河北 邯郸 056038
基金项目:国家科技支撑计划(2014BAC13B06);国家自然科学基金资助项目(51708443,51378414);陕西省污水处理与资源化创新团队(IRT2013KCT-13);中国博士后科学基金(2017M623326XB)
摘    要:基于二维相关光谱分析,对污水厂二级出水难凝聚有机物的臭氧化特性进行了研究.结果表明,混凝很难去除污水厂二级出水中的溶解性有机物,污水厂二级出水溶解性有机物大部分属于难凝聚有机物,以腐殖酸类物质为主.臭氧氧化可以降低二级出水混凝后上清液的色度及UV254,去除率分别可达到70%和40%以上,但是对难凝聚有机物的去除率较低,去除率在10%以下,只是与难凝聚有机物进行了反应,改变其性质.同时,臭氧可以降低二级出水中难凝聚有机物的荧光强度,其中腐殖酸类物质的荧光强度降低较为明显.基于不同臭氧投加量下难凝聚有机物的同步荧光分析,可以得到二级出水难凝聚有机物的二维相关光谱,结果表明,腐殖酸类物质对臭氧氧化最为敏感,腐殖酸类物质与富里酸类物质相比会优先和臭氧反应.

关 键 词:臭氧氧化  二维相关光谱  难凝聚有机物  荧光特性  
收稿时间:2017-08-13

Ozonation characteristics of low coagulability organics based on two dimensional correlation analysis
JIN Xin,HOU Rui,SONG Ji-na,JIN Peng-kang,WANG Xiao-chang.Ozonation characteristics of low coagulability organics based on two dimensional correlation analysis[J].China Environmental Science,2018,38(3):923-928.
Authors:JIN Xin  HOU Rui  SONG Ji-na  JIN Peng-kang  WANG Xiao-chang
Institution:1. Department of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China;2. College of Energy and Environmental Engineering, Hebei University of Engineering, Handan 056038, China
Abstract:Based on two dimensional correlation analysis,the characteristics of low coagulability organic matters from WWTP effluent during ozonation were studied.The results showed that coagulation can hardly remove dissolved organic matters in WWTP effluent,and most of dissolved organic matters in WWTP effluent belonged to low coagulability organic matters,which mainly contained humic-like substances.Color and UV254 of coagulated supernatant can be removed by ozonation with removal efficiency higher than 70% and 40% respectively.However,the removal efficiency of low coagulability organic matters was low (lower than 10% removal efficiency) indicating the organic matter characteristics variation caused by ozonation.Furthermore,the fluorescence intensity could be reduced by ozonation,and the fluorescence intensity of humic-like substances exhibited highest decrease.According to the results of synchronous fluorescence spectra at different ozone dosages,two dimensional correlation spectra can be obtained.The results indicated that humic-like substances were most sensitive fractions to ozonation in low coagulability organics from WWTP,and ozone would preferentially react with humic-like substances rather than fulvic-like substances.
Keywords:ozonation  two dimensional correlation analysis  low coagulability organics  fluorescent characteristics  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国环境科学》浏览原始摘要信息
点击此处可从《中国环境科学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号