首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Control of membrane fouling during hyperhaline municipal wastewater treatment using a pilot-scale anoxic/aerobic-membrane bioreactor system
Authors:Jingmei Sun  Jiangxiu Rong  Lifeng Dai  Baoshan Liu and Wenting Zhu
Institution:1. School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China
2. School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China;CNOOC Tianjin Chemical Research & Design Institute, Tianjin 300131, China
Abstract:Membrane fouling limits the effects of long-term stable operation of membrane bioreactor (MBR). Control of membrane fouling can extend the membrane life and reduce water treatment cost effectively. A pilot scale anoxic/aerobic-membrane bioreactor (A/O-MBR, 40 L/hr) was used to treat the hyperhaline municipal sewage from a processing zone of Tianjin, China. Impact factors including mixed liquid sludge suspension (MLSS), sludge viscosity (micro), microorganisms, extracellular polymeric substances (EPS), aeration intensity and suction/suspended time on membrane fouling and pollution control were studied. The relationships among various factors associated with membrane fouling were analyzed. Results showed that there was a positive correlation among MLSS, sludge viscosity and trans-membrane pressure (TMP). Considering water treatment efficiency and stable operation of the membrane module, MLSS of 5 g/L was suggested for the process. There was a same trend among EPS, sludge viscosity and TMP. Numbers and species of microorganisms affected membrane fouling. Either too high or too low aeration intensity was not conducive to membrane fouling control. Aeration intensity of 1.0 m3/hr (gas/water ratio of 25:1) is suggested for the process. A long suction time caused a rapid increase in membrane resistance. However, long suspended time cannot prevent the increase of membrane resistance effectively even though a suspended time was necessary for scale off particles from the membrane surface. The suction/suspended time of 12 min/3 min was selected for the process. The interaction of various environmental factors and operation conditions must be considered synthetically.
Keywords:hyperhaline municipal sewage  anoxic/oxic membrane bioreactor  membrane fouling control  relationship of various factors
本文献已被 CNKI 维普 万方数据 PubMed 等数据库收录!
点击此处可从《环境科学学报(英文版)》浏览原始摘要信息
点击此处可从《环境科学学报(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号