首页 | 本学科首页   官方微博 | 高级检索  
     检索      

在役悬索管道抗风性能研究及结构退化分析*
引用本文:罗雨菲,帅健,田中山,杨文,许葵.在役悬索管道抗风性能研究及结构退化分析*[J].中国安全生产科学技术,2020,16(9):43-49.
作者姓名:罗雨菲  帅健  田中山  杨文  许葵
作者单位:(1.中国石油大学(北京) 安全与海洋工程学院,北京 102249;2.中国石化销售股份有限公司 华南分公司,广东 广州 510620)
基金项目:* 基金项目: 国家自然科学基金项目(51874324),国家重点研发计划项目(2016YFC0802105),中国石油化工股份有限公司科研基金项目(318019-4)
摘    要:为提高在役成品油悬索跨越管道结构及性能的可靠性,保障长输油气管道生产运营的安全,建立某在役成品油悬索跨越管道的有限元力学仿真模型,研究风载荷对悬索跨越管道的影响作用,探讨主索、吊索等主要构件性能退化时对悬索管道安全性的影响规律。结果表明:通过有限元模拟可以得到管道失效风速为60 m/s,远大于极限风速,且涡激振动振幅很小;主索腐蚀、吊索断裂以及是否存在抗风索这3种情况均能影响结构的安全性。相关企业应当对结构的重要构件进行定期检修,以保障生产运营安全。

关 键 词:悬索跨越管道  风载荷  缆索性能退化  安全性评价

Research on wind resistance performance and analysis on structural degradation of cable suspended pipeline in service
LUO Yufei,SHUAI Jian,TIAN Zhongshan,YANG Wen,XU Kui.Research on wind resistance performance and analysis on structural degradation of cable suspended pipeline in service[J].Journal of Safety Science and Technology,2020,16(9):43-49.
Authors:LUO Yufei  SHUAI Jian  TIAN Zhongshan  YANG Wen  XU Kui
Institution:(1.College of Safety and Ocean Engineering,China University of Petroleum (Beijing),Beijing 102249,China;2.South China Branch,SINOPEC Sales Company,Guangzhou Guangdong 510620,China)
Abstract:In order to improve the reliability of structure and performance of the oil products cable suspended crossing pipelines in service,and ensure the production and operation safety of long distance oil and gas pipeline,a finite element mechanical simulation model of a certain oil products cable suspended crossing pipeline in service was established.The influence of wind load on the cable suspended crossing pipeline was studied,and the influence laws of the performance degradation of main cable,sling and other main components on the safety of cable suspended pipeline was discussed.The results showed that through the finite element simulation,the failure wind speed of the pipeline was 60 m/s,which was much greater than the limit wind speed,and the amplitude of vortex induced vibration was very small.Meanwhile,all the corrosion of main cable,the breakage of sling and the existence of wind resistant cable could affect the structure safety.The relevant enterprises should carry out the regular maintenance on the important components of the structure,so as to ensure the safety of production and operation.
Keywords:cable suspended crossing pipeline  wind load  cable performance degradation  safety evaluation
本文献已被 CNKI 等数据库收录!
点击此处可从《中国安全生产科学技术》浏览原始摘要信息
点击此处可从《中国安全生产科学技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号