首页 | 本学科首页   官方微博 | 高级检索  
     


Metal contamination of drinking water from corrosion of distribution pipes
Authors:Alam I A  Sadiq M
Affiliation:Water Resources and Environment Division, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia.
Abstract:The objectives of this study were to evaluate metal contamination of drinking water resulting from the corrosion of distribution pipes and its significance to human health. A community in Dhahran, which is served from its own desalination facilities, was chosen for this study. About 150 drinking water samples were collected and analyzed for metal concentrations using an inductively coupled argon plasma analyzer. It was found that copper, iron and zinc in the drinking water increased during its transportation from the desalination plant to the consumers. This increase was related to the length and material of distribution pipes. Concentrations of copper and zinc were increased during overnight storage of water in the appliances. Metal concentrations found in this study are discussed with reference to human health.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号