PCDDs and PCDFs in water, sludge and air samples from various levels in a waste water treatment plant with respect to composition changes and total flux |
| |
Authors: | C. N f, D. Broman, R. Ishaq,Y. Zebü hr |
| |
Affiliation: | C. Näf*, D. Broman, R. Ishaq,Y. Zebühr, |
| |
Abstract: | A flux estimate of PCDDs and PCDFs through a waste water treatment plant has been made on an annual basis. The samples were collected from different steps in the treatment procedure within the plant i.e. inlet and outlet water, different sludge types and air samples. From the surroundings of the plant were collected samples of urban air, storm sewer water (urban runoff), plant discharge water and settling particulates from a sediment trap downstream the plant discharge. Differences in congener profiles were found between the samples taken within the plant compared to those collected outside. The flux of PCDD and PCDF equivalents through the plant was found to be approximately 0.4 – 0.5 g/year and the major part was taken away as digested sludge. |
| |
Keywords: | PCDD PCDF digested sludge, water, air, storm sewer, waste water treatment plant, flux, settling particulate matter, urban runoff |