首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Effects of medium-pressure UV lamps radiation on water quality in a chlorinated indoor swimming pool
Authors:Cassan Delphine  Mercier Béatrice  Castex Françoise  Rambaud André
Institution:UPRES 2991, Efficience et Déficience Motrices, Faculté des Sciences du Sport, Université Montpellier 1, 34090 Montpellier, France. delphine.cassan@univ-montp1.fr
Abstract:The aim of our study was to determine the impact of medium-pressure UV lamps radiation on water quality in a chlorinated indoor swimming pool. An indoor swimming pool was equipped with two medium-pressure UV lamps. We collected eight samples of water daily over a four-weeks period and measured total and free chlorine, pH, water temperature, bacteriological parameters, total organic carbon and trihalomethanes. During the first week, which served as control, medium-pressure UV lamps were turned off. During the next three weeks, medium-pressure UV lamps were kept on 24 h per day. The third week, we reduced the level of the injected chlorine into water, and the last week we also reduced the water renewal volume by 27%. Our results showed that bacteriological parameters remained within allowable french limits. When medium-pressure UV lamps were kept on, total, free and active chlorine levels were significantly increased (P<0.001), whereas combined chlorine level were significantly decreased (P<0.001 and P<0.05, respectively). The levels of chloroform and bromodichloromethane were significantly increased when medium-pressure UV lamps were kept on (P<0.001), whereas chlorodibromomethane and bromoform levels significantly decreased (P<0.05 and P<0.001, respectively). The additional formation of chloroform and bromodichloromethane may be explained by the increase in active chlorine and by radicalizing mechanisms initiated by UV radiation.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号