首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A field evaluation of a piezo-optical dosimeter for environmental monitoring of nitrogen dioxide
Authors:Wright John D  Schillinger Eric F J  Cazier Fabrice  Nouali Habiba  Mercier Agnes  Beaugard Charles
Institution:School of Physical Sciences, University of Kent, Canterbury, Kent, UK CT2 7NR.
Abstract:Measurements of 8-hour time-weighted average NO(2) concentrations are reported at 7 different locations in the region of Dunkirk over 5 consecutive days using PiezOptic monitoring badges previously calibrated for the range 0-70 ppb together with data from chemiluminescent analysers in 5 sites (4 fixed and one mobile). The latter facilities also provided data on ozone and NO concentrations and meteorological conditions. Daily averages from the two pairs of badges in different types of sampling cover in each site have been compared with data from the chemiluminescent analysers, and found largely to agree within error margins of +/-30%. Although NO(2) and ozone concentrations were low, rendering detailed discussion impossible, the general features followed expected patterns.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏