首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Formulation and Validation of an Empirical Moisture Damage Index
Authors:Ulla Haverinen  Mikko Vahteristo  Juha Pekkanen  Tuula Husman  Aino Nevalainen  Demetrios Moschandreas
Institution:(1) Laboratory of Environmental Microbiology and Unit of Epidemiology, National Public Health Institute, POB 95, FIN-70701 Kuopio, Finland;(2) Chemical and Environmental Engineering, Illinois Institute of Technology, 10 West 33rd Street, Perlstein Hall, Room 127, Chicago, Illinois 60616-3793, USA
Abstract:An empirical moisture damage index was developed in order to reduce the subjectivity of the estimation of moisture damage in domestic residences, in relation to occupant health. The database was generated using information gathered from a sample of 164 houses that were examined by civil engineers, and questionnaire data collected from the occupants. The index was formulated to associate with the occupant reported respiratory symptoms by calculating weighted estimates of selected moisture damage attributes using 80% of the sample. The remaining 20% of the sample was used to verify the final index. The index associated strongly with the health symptoms of interest. This index is a tool that may be used as an indicator of moisture damage induced exposure in domestic residences.
Keywords:building investigation  exposure modeling  indoor air  mold  residences  respiratory symptoms
本文献已被 SpringerLink 等数据库收录!