首页 | 本学科首页   官方微博 | 高级检索  
     检索      

有机磷阻燃剂生产废水预处理工艺研究
引用本文:欧云川,程迪,马文静,宋红,孙宇明.有机磷阻燃剂生产废水预处理工艺研究[J].化工环保,2012,32(1):44-48.
作者姓名:欧云川  程迪  马文静  宋红  孙宇明
作者单位:沈阳化工研究院设计工程有限公司,辽宁沈阳,110021
摘    要:采用液膜萃取—酸析沉降—络合萃取组合工艺对有机磷阻燃剂生产废水进行预处理.最佳工艺条件为:液膜萃取时,液膜油相(表面活性剂与煤油的混合液)与内水相(H2SO4溶液)的体积比2∶1、乳化液膜与废水的体积比1∶8、废水pH 13.0,硫酸体积分数10%、煤油中表面活性剂质量浓度30 g/L、液膜萃取时间 15 min;酸析沉降时,废水pH l.0,酸析沉降时间30 min;络合萃取时,络合萃取剂(烷基叔胺N235与煤油的混合液)中烷基叔胺N235体积分数30%,络合萃取剂与废水的体积比1∶4,废水pH l.0,络合萃取时间30 min.在此最佳处理条件下,废水COD总去除率可达93%,吡啶去除率达99.9%以上,总磷去除率可达97%,BOD5/COD提高至0.32,有利于后续生化处理.

关 键 词:有机磷阻燃剂  液膜萃取  酸析  络合萃取  吡啶  废水处理

Research on Pre-treatment Process for Wastewater from Organophosphorus Flame Retardant Production
Ou Yunchuan , Cheng Di , Ma Wenjing , Song Hong , Sun Yuming.Research on Pre-treatment Process for Wastewater from Organophosphorus Flame Retardant Production[J].Environmental Protection of Chemical Industry,2012,32(1):44-48.
Authors:Ou Yunchuan  Cheng Di  Ma Wenjing  Song Hong  Sun Yuming
Institution:(Design and Engineering Co.Ltd.,Shenyang Research Institute of Chemical Industry,Shenyang Liaoning 110021,China)
Abstract:Wastewater from organophosphorus flame retardant production was pre-treated by the combined process of liquid membrane extraction-acid precipitation-complexation extraction.The optimum process conditions are as follows:For liquid membrane extraction,volume ratio of oil phase(mixture of surfactant and kerosene)to internal phase(H2SO4 solution)2∶1,volume ratio of emulsion liquid membrane to wastewater 1∶8,wastewater pH 13.0,volume fraction of H2SO4 solution 10%,mass concentration of surfactant in kerosene 30 g/L,liquid membrane extraction time 15 min;For acid precipitation,wastewater pH 1.0,acid precipitation time 30 min;For complexation extraction,volume fraction of alkyl tertiary amine N235 in complexation extractant(mixture of alkyl tertiary amine N235 and kerosene) 30%,volume ratio of complexation extractant to wastewater 1∶4,wastewater pH 1.0,complexation extraction time 30 min.Under these conditions,the total COD removal rate can reach 93%,the pyridine removal rate can reach above 99.9%,the TP removal rate can reach 97%,and the BOD5 /COD value can increase to 0.32,which is of great advantage to the further bio-treatment.
Keywords:organophosphorus flame retardant  liquid membrane extraction  acid precipitation  complexation extraction  pyridine  wastewater treatment