离子色谱法测定空气中氟化氢氯化氢和硫酸
引用本文:田小萌.离子色谱法测定空气中氟化氢氯化氢和硫酸[J].环境监测管理与技术,2012,24(2):54-56.
作者姓名:田小萌
作者单位:云南省环境监测中心站,云南 昆明,650034
摘    要:以多孔玻板吸收管采样,采用离子色谱法同时测定作业场所空气中的氟化氢、氯化氢和硫酸,采样效率>92%。氟化氢在0 mg/L~2.00 mg/L、氯化氢在0 mg/L~2.50 mg/L、硫酸在0 mg/L~4.00 mg/L范围内线性良好,检出限分别为0.003 mg/m3、0.02 mg/m3、0.023 mg/m3(按采样体积60 L计),标准溶液平行测定的RSD≤8.0%,两个质量浓度水平加标的平均回收率为92.6%~106%。

关 键 词:氟化氢  氯化氢  硫酸  离子色谱法  空气

Determination for Hydrogen Fluoride, Chlorine Hydride and Sulphuric Acid in the Air by Ion Chromatography
TIAN Xiao-meng.Determination for Hydrogen Fluoride, Chlorine Hydride and Sulphuric Acid in the Air by Ion Chromatography[J].The Administration and Technique of Environmental Monitoring,2012,24(2):54-56.
Authors:TIAN Xiao-meng
Institution:TIAN Xiao-meng(Yunnan Environmental Monitoring Center,Kunming,Yunnan 650034,China)
Abstract:The hydrogen fluoride,chlorine hydride and sulphuric acid in the air were determined by sampling of multi-hole absorbing tubes and testing of ion chromatography.The results showed the sampling efficiency92%;good linearity ranged from 0 mg/L to 2.00 mg/L for hydrogen fluoride,from 0 mg/L to 2.50 mg/L for chlorine hydride,from 0 mg/L to 4.00 mg/ for sulphuric acid;detection limits 0.003 mg/m3 for hydrogen fluoride,0.02 mg/m3 for chlorine hydride and 0.023 mg/m3 for sulphuric acid(air sampling volume 60 L);RSD of standard solution duplicates≤8.0%;average spiked recoveries of two concentration levels from 92.6% to 106%.
Keywords:Hydrogen fluoride  Chlorine hydride  Sulphuric acid  Ion chromatography  Air