Abstract: | In this study, solid-gas partitioning coefficients of PAHs on fly ash in stack gas from a municipal incinerator were determined according to elution analysis with gas-solid chromatography. The fly ash from the electrostatic precipitator was sieved and packed into a 1/4 inch (6.3 mm) pyrex column. Elution analysis with gas-solid chromatography was conducted for three PAHs, Napthalene, Anthracene, and Pyrene. The temperature for elution analysis was in the range of 100°C to 300°C. Vg, specific retention volume obtained from elution analysis, and S, specific surface area of fly ash measured by a surface area measurement instrument, were used to estimate the solid-gas partitioning coefficient, KR. In addition, the relationships between KR and temperature and KR and PAH concentrations were investigated. |