首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Evaluation of a Low-Cost Transient Mass Measurement System in Vehicle Inspection and Maintenance Testing: Results of a Gordon-Darby Study
Authors:Carl Ensfield  Jay Gordon Jr  Jim Lindner
Institution:1. Sensors, Inc. , Saline , Michigan , USA censfield@sensors-inc.com;3. Gordon-Darby, Inc , Louisville , Kentucky , USA;4. U.S. Environmental Protection Agency , Ann Arbor , Michigan , USA
Abstract:Abstract

A study was performed at a Gordon-Darby centralized inspection and maintenance (I/M) test lane in Phoenix, AZ, in December 1999 for the purpose of evaluating the accuracy of production Vehicle Mass Analysis System (VMAS) equipment relative to standard IM240 equipment. Simultaneous transient mass measurements were made on random vehicles using VMAS and IM240 systems on two test lanes during regular I/M testing. Cumulative mass emissions for 846 valid tests were correlated using least-squares regression analysis. Correlation indices were >0.99 for both carbon monoxide (CO) and nitric oxide (NO) and 0.93 for hydrocarbon (HC), and the standard errors of regression were 1.38 g/mi, 0.123 g/mi, and 0.245 g/mi for CO, NO, and HC, respectively. These strong correlation results are reflected by high excess emission identification rates of 99.4% for CO, 99.3% for NO, and 94.5% for HC when applying final IM240 cut points with a <2% error of commission for all pollutants.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号