首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Validation of the Digital Opacity Compliance System under Regulatory Enforcement Conditions
Authors:Michael J McFarland  Steve L Rasmussen  Daniel A Stone  Glenn R Palmer  Joseph D Wander
Institution:1. Department of Civil and Environmental Engineering , Utah State University , Logan , UT , USA farlandm@msn.com;3. 75th CEG/CEVC , Hill Air Force Base, UT , USA;4. Engineering and Services Research Laboratory , Tyndall Air Force Base, FL , USA
Abstract:Abstract

U.S. Environmental Protection Agency (EPA) Emission Measurement Center in conjunction with EPA Regions VI and VIII, the state of Utah, and the U.S. Department of Defense have conducted a series of long-term pilot and field tests to determine the accuracy and reliability of a visible opacity monitoring system consisting of a conventional digital camera and a separate computer software application for plume opacity determination. This technology, known as the Digital Opacity Compliance System (DOCS), has been successfully demonstrated at EPA-sponsored Method-9 “smoke schools,” as well as at a number of government and commercially operated industrial facilities.

Results from the current DOCS regulatory pilot study demonstrated that, under regulatory enforcement conditions, the average difference in opacity measurement between the DOCS technology and EPA Reference Method 9 (Method 9) was 1.12%. This opacity difference, which was computed from the evaluation of 241 regulated air sources, was found to be statistically significant at the 99% confidence level. In evaluating only those sources for which a nonzero visible opacity level was recorded, the average difference in opacity measurement between the DOCS technology and Method 9 was 1.20%. These results suggest that the two opacity measurement methods are essentially equivalent when measuring the opacity of visible emissions.

Given the costs and technical limitations associated with use of Method 9, there is a recognized need to develop accurate, reproducible, and scientifically defensible alternatives to the use of human observers. The use of digital imaging/processing brings current technology to bear on this important regulatory issue. Digital technology offers increased accuracy, a permanent record of measurement events, lower costs, and a scientifically defensible approach for opacity determination.