首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Fine Particle (PM25) Measurement Methodology,Quality Assurance Procedures,and Pilot Results of the EXPOLIS Study
Authors:Kimmo J Koistinen  Anu Kousa  Virpi Tenhola  Otto Hänninen  Matti J Jantunen  Lucy Oglesby
Institution:1. Division of Environmental Health , National Public Health Institute , Kuopio , Finland;2. Institute of Social and Preventive Medicine, University of Basel , Basel , Switzerland
Abstract:ABSTRACT

EXPOLIS is a European multicenter (Athens, Basel, Grenoble, Helsinki, Milan, and Prague) air pollution exposure study. It is the first international, population-based, large-scale study, where personal exposures to PM2 5 aerosol particles (together with volatile organic compounds and carbon monoxide) are being monitored. EXPOLIS is performed in six different centers across Europe, the sampled aerosol concentrations vary greatly, and the mi-croenvironmental samples are not collected with the same equipment as the personal samples. Therefore careful equipment selection, methods development and testing, and thorough quality assurance and quality control (QA & QC) procedures are essential for producing reliable and comparable PM2.5 data. This paper introduces the equipment, the laboratory test results, the pilot results, the standard operating procedures, and the QA & QC procedures of EXPOLIS. Test results show good comparability and repeatability between personal and microenvironmen-tal monitors for PM2.5 at different concentration levels measured across Europe in EXPOLIS centers.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号