首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Validation of a conductometric bienzyme biosensor for the detection of proteins as marker of organic matter in river samples
Authors:KHADRO Basm  NAMOUR Philippe  BESSUEILLE Franc?ois  LEONARD Didier and JAFFREZIC-RENAULT Nicole
Institution:1. University of Lyon, Laboratory of Analytical, CNRS UMR 5180, 69622 Villeurbanne, France;Cemagref of Lyon, 3 Bis Quai Chauveau, 69336 Lyon, France
2. Cemagref of Lyon, 3 Bis Quai Chauveau, 69336 Lyon, France
3. University of Lyon, Laboratory of Analytical, CNRS UMR 5180, 69622 Villeurbanne, France
Abstract:This article describes a conductometric bi-layer based bienzyme biosensor for the detection of proteins as a marker of organic matter in rivers. Proteins were chosen to be used as indicators of urban pollution. The working mechanism of the bienzyme biosensor is based on the enzymatic hydrolysis of proteins into several fractions (peptides and amino acids), which results in a local conductivity change depending of the concentration of proteins. In this work, we began with the optimization of biosensor response using bovine serum albumin (BSA) as standard protein. For this objective seven enzymatic biosensors were prepared: four enzymatic sensors with only one layer of enzyme (proteinase K, trypsin, pronase or protease X) and three other enzymatic sensors with two layers (first layer: membrane containing proteinase K, second layer: one of the three other enzymes: trypsin, pronase or protease X). The biosensors were obtained through the deposition of enzymatic layers and the cross-linking process between enzymes and BSA in saturated glutaraldehyde vapour. The response of the various biosensors, described previously, were compared with the values of total organic carbon (TOC), and those of organic nitrogen (Norg), as determined by the laboratory accredits (CEMAGREF of Lyon) using the traditional method of analysis (NF EN 1484, infrared spectroscopy) and (NF EN 25663, mineralization/colorimetry assay) respectively for each water sample obtained from different sites in Lyon (France). The linear correlations obtained with the response of the seven biosensors showed the most important indices of correlations for the biosensor with two enzymatic layers: proteinase K + pronase (pkp). The optimum conditions for the preparation of the pkp biosensor increased the sensitivity and gave a limit of quantification of 0.583 μg/L for TOC and 0.218μg /L Norg in water samples. This sensor shows good reproducibility (2.28 %), a capacity to be used at temperatures range 10-30℃ (depending on the season) and moreover a long lifetime (5 weeks).
Keywords:conductometric biosensor  proteins  enzyme  natural water analyses  total organic carbon  organic nitrogen
本文献已被 CNKI 维普 万方数据 ScienceDirect 等数据库收录!
点击此处可从《环境科学学报(英文版)》浏览原始摘要信息
点击此处可从《环境科学学报(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号