跌落保险监测装置的设计与应用
引用本文:胡晓耘,叶赞,贺生斌.跌落保险监测装置的设计与应用[J].防灾减灾工程学报,2018(3):48-51.
作者姓名:胡晓耘  叶赞  贺生斌
作者单位:国网宁夏电力有限公司培训中心,宁夏银川 750011;国网宁夏电力有限公司电力科学研究院,宁夏银川 750011
摘    要:为实现对配电线路及跌落保险的实时监测,设计了一套针对跌落保险的故障监测定位装置。该装置可以实时准确上报故障信息及跌落保险状态,利用装置的GPS定位功能配合数据中心及移动端软件,能够帮助运行人员迅速到达故障位置。现场安装及应用结果表明跌落保险监测装置能迅速可靠定位线路故障并上传故障信息,加快抢修速度,减少停电时间,提高供电可靠性。

关 键 词:10  kV配电网  跌落保险  GPS定位  故障监测

Design and application of drop type fuse monitoring device
HU Xiaoyun,YE Zan,HE Shenbin.Design and application of drop type fuse monitoring device[J].Journal of Disaster Prevent and Mitigation Eng,2018(3):48-51.
Authors:HU Xiaoyun  YE Zan  HE Shenbin
Abstract:In order to realize the real-time monitoring of the distribution transmission line and dropfuse, a set of fault monitoring positioning device for the drop fuse was designed. The device can accu-rately real-time upload the fault information and drop fuse states, with the use of GPS and data cen-ter and mobile terminal software , operators can quickly reach the position of the fault happening. Theapplication results show that the drop type fuse monitoring device can fast and reliably orientate theline fault and upload the fault information, quicken the recovery speed , reduce the power outage timeand improve the power supply reliability.