首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Equilibration times,compound selectivity,and stability of diffusion samplers for collection of ground-water VOC concentrations
Institution:4. Department of Neurosurgery, University of California, San Francisco, San Francisco, California, USA
Abstract:Vapor-filled polyethylene diffusion samplers (typically used to locate discharge zones of volatile organic compound contaminated ground water beneath streams and lakes) and water-filled polyethylene diffusion bag samplers (typically used to obtain volatile organic compound concentrations in ground-water at wells) were tested to determine compound selectivity, equilibration times, and sample stability. The aqueous concentrations of several volatile organic compounds obtained from within water-filled diffusion samplers closely matched concentrations in ambient water outside the samplers. An exception was methyl-tert-butyl ether, which was detectable, but not reliably quantifiable using the diffusion samplers. The samplers equilibrated to a variety of volatile organic compounds within 24 h for vapor-filled passive diffusion vial samplers and within 48 h for water-filled passive diffusion bag samplers. Under field conditions, however, a longer equilibration time may be required to account for environmental disturbances caused by sampler deployment. An equilibrium period for both vapor- and water-filled diffusion samplers of approximately 2 weeks probably is adequate for most investigations in sandy formations. Longer times may be required for diffusion-sampler equilibration in poorly permeable sediment. The vapor-filled samplers should be capped and water from the diffusion bag samplers should be transferred to sampling vials immediately upon recovery to avoid volatilization losses of the gasses.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号