Comparison of an open path differential optical absorption spectroscopy system and a conventional in situ monitoring system on the basis of long-term measurements of SO2, NO2, and O3
Institution:1. Department of Electrical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 790-784, Republic of Korea;2. Division of IT Convergence Engineering, Pohang University of Science and Technology (POSTECH), Pohang 790-784, Republic of Korea;3. Department of Creative IT Engineering and Future IT Innovation Lab., Pohang University of Science and Technology (POSTECH), Pohang 790-784, Republic of Korea;1. Key Laboratory of Opto-Electronic Information Acquisition and Manipulation of Ministry of Education, Anhui University, 230601 Hefei, China;2. Laser Spectroscopy and Sensing Laboratory, Anhui University, 230601 Hefei, China;3. China Aerodynamics Research and Development Center, 621000 Mianyang, China;1. The Key Laboratory of Cancer Biomarkers, Prevention & Treatment Cancer Center, Nanjing Medical University, No. 140 Hanzhong Road, Nanjing 210029, China;2. The Key Laboratory of Antibody Technique of Ministry of Health, Nanjing Medical University, No. 140 Hanzhong Road, Nanjing 210029, China;3. Department of Otolaryngology-Head and Neck Surgery, The First Affiliated Hospital of Nanjing Medical University, No. 300 Guangzhou Road, Nanjing 210011, China;4. Department of Gynecology and Obstetrics, Nanjing Maternal and Children Care Hospital, Nanjing Medical University, Nanjing 210029, China;5. Department of Pathology, Affiliated Hospital of Nantong University, No. 20 Xisi Road, Nantong 226001, China;6. Department of Otolaryngology-Head and Neck Surgery, The Second Affiliated Hospital of Nanjing Medical University, No. 121 Jiang Jia Yuan, Nanjing 210011, China;7. Department of Pathology, The Second Affiliated Hospital of Nanjing Medical University, No. 121 Jiang Jia Yuan, Nanjing 210011, China;8. Department of Otolaryngology-Head and Neck Surgery, Jiangsu Provincial Hospital, No. 65 Jiangsu Road, Nanjing 210029, China;9. Huadong Medical Institute of Biotechniques, No. 293 Zhongshan Dong Road, Nanjing 210002, China
Abstract:A field-based intercomparison study was conducted to evaluate the performance of a line-integrating monitoring technique (a commercial differential optical absorption spectroscopy, DOAS, system by Opsis AB, Sweden) in concert with a conventional in situ monitoring technique (MACSAM-2 (or MS2) system, Japan). In the course of our study, the mixing ratios of three trace gases including SO2, NO2, and O3 were measured routinely from the Ban Po district of Seoul during a 13 month period (June 1999–August 2000). The data obtained from two different systems were used to evaluate various aspects of DOAS performance. The differences in the observed mixing ratios between two techniques, if assessed in terms of the percent difference (PD) values between different data sets, were in general rather compatible not only among different species but also as a function of varying time scale. The differences in the measured mixing ratio between the two systems were also examined statistically using linear regression analysis. Results of the regression analysis indicated the existence of significant correlations among all trace gases monitored, confirming the strong compatibility between the two systems. The effects of meteorological factors on the DOAS performance were also examined through investigation of the mixing ratio differences between two systems and the concurrently determined environmental parameters. According to our analysis, it is concluded that the level of agreement between the two systems can be affected by the variations in the spatial mixing conditions. Although some uncertainties remain to be resolved, our preliminary attempts to evaluate an open path monitoring technique clearly demonstrated that consideration of meteorological conditions may be required to properly assess the DOAS performance due to its capacity to cover spatial scale over the open path length.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号