Abstract: | ABSTRACT: Evaporative heat loss is an essential component of any heat budget used for the modeling of lake water temperatures. Seven evaporative heat loss equations were tested in a year-round, physically-based temperature and dissolved oxygen model for lakes. Deciding which equation to choose for use in the year-round model was based on the goodness of fit of the simulated vs. measured surface temperatures, which were taken at a depth of 1 m below the water surface. An equation which includes free and forced convection components and which was previously used for cooling ponds gave the best fit between temperature simulations and measurements. |