首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Sensitivity analysis of ground-level ozone concentration to emission changes in two urban regions of southeast Texas
Authors:Lin Che-Jen  Ho Thomas C  Chu Hsing-wei  Yang Heng  Chandru Santosh  Krishnarajanagar Nagesh  Chiou Paul  Hopper Jack R
Institution:Department of Civil Engineering, Lamar University, Beaumont, TX 77710, USA. lincx@hal.lamar.edu
Abstract:Air pollutant emission is one of the predominant factors affecting urban air quality such as ground-level ozone formation. This paper assesses the impact of changing emission inventory scenarios, based on combinations of point, mobile, area/non-road and biogenic sources, on the tropospheric ozone concentration in two southeast Texas urban areas, i.e. Houston-Galveston and Beaumont-Port Arthur, during the rapid ozone formation event (ROFE) on August 25, 2000. The EPA's Community Multiscale Air Quality (CMAQ) modeling system with 1999 national emission inventory (NEI99) estimates and updated SAPRC99 chemical mechanism are used in the sensitivity analysis for twelve different emission scenarios. Based on model results, it is found that the point source emission of NOx and VOC contributes the greatest ozone peak in the ROFE. Removing Texas point sources of VOC and NOx emission from the inventory results in a reduction in peak O3 concentration by 128 and 70 ppbv in Houston urban area, respectively. Similar but less drastic impact from point source is also observed in the Beaumont-Port Arthur area. The effect on peak ozone concentration due to mobile, area and non-road sources emissions are less significant compared to that of point source emission. Reducing VOC emission appears to be more effective than reducing NOx emission in lowering peak O3 concentration in the studied region. Although biogenic emission can contribute up to 37 ppbv of peak ozone level over a large area, the affected area is away from the urban region of concern, and should not be the main cause for O3 non-attainment in the two urban areas. Removing CO emission from mobile sources does not lead to significant reduction (< 1 ppbv) in ozone concentrations. The modeled data also show that the transport of O3 precursors from adjacent states can cause a significant ozone plume near Beaumont due to its proximity to the state border based on the conditions during the August 25, 2000 O3 episode.
Keywords:Ground-level ozone  Sensitivity analysis  Emission inventory  Air quality modeling
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号