Abstract: | The data on dioxin and furan emissions revealed, based on individual analysis for 2,3,7,8-TCDD, TCDD, 2,3,7,8-TCDF and TCDF for the six test periods and the operation of the two RDF-fired boilers, that there is no apparent consistent relationship between the dioxin and furan emissions and the individual or combined (averaged) boiler steam flow, total flue gas flow, sidewall furnace temperature, furnace temperature at 2-second residence time, or total furnace residence time at this plant. Only RDF feeder balance begins to show a correlation. However, there was a difference between RDF-natural gas firing and RDF-only firing; the RDF-only firing had lower PCDD and PCDF emissions while consistently operating at lower excess air. The dioxin and furan emissions from this testing are comparable to the low end of the range of these emissions measured by the U.S. EPA at resource recovery plants in the past 4 years. This may be due in part to the calculated average furnace retention of 4 to 5 seconds during Tests #4–6, with average furnace temperatures at 2-second residence time from 1650°F to 1750°F. However, there was no correlation between dioxin and furan emissions in the stack and individual boiler operation, as judged by the average concentrations of O2, CO, CO2, 1-CO/CO2), NOx, HCl, SO2, or TSP, and furnace upset conditions versus normal operation as judged by instantaneous steam flow, sidewall furnace temperature, O2, CO, NOx, or SO2. |