粉末活性炭应急处理阿特拉津突发污染原水的研究
引用本文:贾丽萍,刘学卿,王新刚,唐玉斌,吕锡武.粉末活性炭应急处理阿特拉津突发污染原水的研究[J].工业安全与环保,2012,38(2):24-26,73.
作者姓名:贾丽萍  刘学卿  王新刚  唐玉斌  吕锡武
作者单位:1. 江苏科技大学环境工程系 江苏镇江212018
2. 东南大学环境工程系 南京210096
基金项目:国家"十一五"863计划项目,江苏科技大学大学生创新计划重点项目
摘    要:以黄浦江上游水源地取水口突发阿特拉津污染为背景,从实验室小试和中试2个尺度上,研究了粉末活性炭(PAC)对阿特拉津污染的应急处理效果。小试结果表明,增大PAC投加量,阿特拉津的去除率显著提高,PAC对各浓度水平阿特拉津污染的去除主要集中在前10 min,历时60 min左右,吸附达到平衡。平衡吸附量随着原水中阿特拉津初始浓度的增大而增大,但PAC对污染物的应急处理效率却随之降低。Fre undlich等温吸附模型较Langmuir模型可更好地拟合PAC对阿特拉津的吸附规律。中试表明,针对10μg/L和20μg/L的阿特拉津污染,分别投加5 mg/L和20mg/L PAC,即可使出水浓度达标;针对100μg/L和200μg/L的阿特拉津污染,投加PAC 50mg/L,出水浓度分别超标7倍和14倍。

关 键 词:阿特拉津  突发污染  应急处理  粉末活性炭

Research on Emergency Treatment of Accidental Atrazine Pollution of Raw Water by Powdered Activated Carbon
JIA Liping , LIU Xueqing , WANG Xing , TANG Yubin , LU Xiwu.Research on Emergency Treatment of Accidental Atrazine Pollution of Raw Water by Powdered Activated Carbon[J].Industrial Safety and Dust Control,2012,38(2):24-26,73.
Authors:JIA Liping  LIU Xueqing  WANG Xing  TANG Yubin  LU Xiwu
Institution:JIA Liping1 LIU Xueqing1 WANG Xingang1 TANG Yubin1 LU Xiwu2(1.Department of Environmental Engineering,Jiangsu University of Science and Technology Zhenjiang,Jiangsu 212018)
Abstract:In the background of atrazine pollution suddenly occurred in Huangpu upriver source water,emergency adsorption treatment efficiency of atrazine by powdered activated carbon(PAC) is researched via laboratory and pilot tests.The laboratory test results shows that the removal rate of atrazine notably increases with PAC dosage.Atrazine at each concentration level can be quickly decreased by PAC in 10 minutes and the adsorption equilibrium is reached in 60 minutes.The equilibrium adsorption capacities increase with initial concentration of atrazine in raw water.But the emergency adsorption treatment efficiency decreases with the rise of initial concentration of atrazine.Freundlich model can better describe the isothermal adsorption law than Langmuir model.Pilot tests show that,for the atrazine pollution with initial concentration of 10 μg/L and 20 μg/L,adding 5 mg/L and 20 mg/L PAC respectively,atrazine concentration of effluent is below standard value.For 100 μg/L and 200 μg/L atrazine contamination,adding PAC 50 mg/L,the average atrazine concentrations of effluent exceeds 7 times and 14 times of standard value.
Keywords:atrazine abrupt pollution emergency treatment powdered activated carbon