基金项目:国家“863”高技术研究发展计划项目(2006AA06Z377);清华大学-三洋环境技术联合研究中心资助项目
摘    要:通过动态法测试水吸收型空气净化器A和活性炭过滤吸附型净化器B对甲醛的去除性能,探索更为合理的方法以评价空气净化器对气态污染物的去除性能.对净化器A去除甲醛的短期测试结果表明,净化器对甲醛浓度为0.3、0.5、0.8和1 mg/m3的连续空气流均有明显的净化效果,对甲醛的去除速率在0.91~2.78 mg/h之间.对净化...

关 键 词:空气净化器  动态测试  甲醛  室内空气

Study on performance of air cleaner to remove formaldehyde by continuous mode
Wang Juan,Zhang Pengyi,Kohei Nozawa and Zhang Lin.Study on performance of air cleaner to remove formaldehyde by continuous mode[J].Techniques and Equipment for Environmental Pollution Control,2011,5(1):137-140.
Authors:Wang Juan  Zhang Pengyi  Kohei Nozawa and Zhang Lin
Institution:Wang Juan1 Zhang Pengyi1 Kohei Nozawa2 Zhang Lin2 (1.Department of Environmental Science and Engineering,Tsinghua University,Beijing 100084,China,2.Sanyo Electric Co.Ltd.,Beijing 100012,China)
Abstract:Continuous test mode was used to evaluate the capability of air cleaner A by water absorption-indirect degradation and air cleaner B which with activated carbon filter to remove formaldehyde, to explore more scientific and reasonable methods for evaluating the air cleaners to remove gaseous pollutants. The air cleaner A showed significant capability to remove formaldehyde from air of initial formaldehyde concentrations of 0.3, 0.5, 0.8 or 1 mg/m3 in continuous mode, and the corresponding removal rates ranged from 0.91 to 2.78 mg/h. The removal rate of the air cleaner A decreased gradually with operation time. However, it recovered and kept long term capability to remove formaldehyde if water could be timely replenished into the electrolysis water bath of the air cleaner. The air cleaner B lost its capability to remove formaldehyde within 30 h in continuous mode. Continuous mode could more scientifically and reasonably evaluate the capability of air cleaners to remove gaseous pollutants, especially their long term capability.
Keywords:air cleaner  continuous test  formaldehyde  indoor air