首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Effect of ignition position on the run-up distance to DDT for hydrogen-air explosions
Authors:Robert Blanchard  Detlef ArndtRainer Grätz  Swen Scheider
Institution:BAM Federal Institute for Materials Research and Testing, Chemical Safety Engineering, Explosion Protection and Risk Assessment, Unter den Eichen 87, 12205 Berlin, Germany
Abstract:The method described in this paper enabled reliable and accurate positioning of an overdriven detonation by calculation of shock wave velocities (detonation and retonation) for hydrogen explosions in a closed 18 m long horizontal DN150 pipe. This enabled an empirical correlation between the ignition position and the run-up distance to DDT to be determined. It was shown that the initial ability of the flame to expand unobstructed and the piston-like effect of burnt gas expanding against the closed end of the tube contributed to initial flame acceleration and hence were able to affect the run-up distance to overdriven detonation. Flame speeds and rates of initial pressure rise were also used to explain how these two competing effects were able to produce a minimum in the run-up distance to DDT. The shortest run-up distance to DDT, relative to the ignition position, for this pipe and gas configuration was found when the ignition position was placed 5.6 pipe diameters (or 0.9 m) from the closed pipe end. The shortest run-up distance to DDT relative to the end of the pipe was recorded when the ignition source was placed 4.4 pipe diameters or 0.7 m from the pipe end.
Keywords:Deflagration to detonation transition (DDT)  Ignition position  Hydrogen  Detonation and retonation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏