首页 | 本学科首页   官方微博 | 高级检索  
     检索      


3-D numerical evaluation of density effects on tracer tests
Institution:1. University of Waterloo, Department of Earth and Environmental Sciences, Ecohydrology, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada;2. Helmholtz Zentrum München, Institute of Groundwater Ecology, Ingolstädter Landstr. 1, 85764 Neuherberg, Germany;3. German Research Centre for Geoscience - GFZ, Hydrology, Telegrafenberg, 14473 Potsdam, Germany;4. Technical University of Munich, Chair of Analytical Chemistry and Water Chemistry, Marchioninistr. 17, 81377 Munich, Germany;5. University of Natural Resources and Life Sciences, Institute of Hydraulics and Rural Water Management, Muthgasse 18, 1190 Vienna, Austria;1. National Institute of Aquatic Resources, Technical University of Denmark, Charlottenlund, Denmark;2. Japan International Research Centre for Agricultural Sciences, Ohwashi, Tsukuba, Ibaraki, Japan
Abstract:In this paper we present numerical simulations carried out to assess the importance of density-dependent flow on tracer plume development. The scenario considered in the study is characterized by a short-term tracer injection phase into a fully penetrating well and a natural hydraulic gradient. The scenario is thought to be typical for tracer tests conducted in the field. Using a reference case as a starting point, different model parameters were changed in order to determine their importance to density effects. The study is based on a three-dimensional model domain. Results were interpreted using concentration contours and a first moment analysis. Tracer injections of 0.036 kg per meter of saturated aquifer thickness do not cause significant density effects assuming hydraulic gradients of at least 0.1%. Higher tracer input masses, as used for geoelectrical investigations, may lead to buoyancy-induced flow in the early phase of a tracer test which in turn impacts further plume development. This also holds true for shallow aquifers. Results of simulations with different tracer injection rates and durations imply that the tracer input scenario has a negligible effect on density flow. Employing model cases with different realizations of a log conductivity random field, it could be shown that small variations of hydraulic conductivity in the vicinity of the tracer injection well have a major control on the local tracer distribution but do not mask effects of buoyancy-induced flow.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号