Abstract: | ABSTRACT: Several methods for synthetic unit hydrographs are available in the literature. Most of these methods involve the hand fitting of a curve over a set of a few hydrograph points, which can sometimes be a subjective task. Besides, the user often finds it difficult or simply neglects to adjust the generated unit graph to a runoff volume of one unit (inch, cm, or mm). It is the purpose of this paper to present to the design hydrologist a simple method to fit a smooth gamma distribution over a single point specified by the unit hydrograph peak and the time to peak with a guaranteed unit depth of runoff. |