Determination of optimum operating conditions for industrial dye wastewater treatment using adaptive heuristic criticism pH control
Authors:Zeybek Z  Yüce Cetinkaya S  Alioglu F  Alpbaz M
Institution:Department of Chemical Engineering, Ankara University, 06100 Tandogan, Ankara, Turkey. zeybek@eng.ankara.edu.tr
Abstract:For a pilot-scale application, pH control in the treatment of highly contaminated dye industrial wastewater containing metallic compounds as the main pollutants has been investigated with a method using adaptive heuristic criticism control (AHCC). Subsequent experimentation on between 12 and 18 l of the wastewater was carried out using statistical experimental design methodology to evaluate the effects of three critical factors: slaked lime (calcium hydroxide, Ca(OH)(2)) concentration, iron chloride (FeCl(3)) concentration and wastewater volume. With these critical factors, the wastewater treatment process is modeled as an appropriate quadratic cost function of the turbidity of the clarified water. The model is optimized with Rosenbrock's method. Response surface topology of the wastewater treatment is given in terms of optimal concentrations of lime water and FeCl(3) and optimal wastewater volume at pH 11.
Keywords:Dye wastewater  Pilot plant  AHCC algorithm  Experimental design  Turbidity  Chemical treatment