首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Monitoring of iodinated X-ray contrast media in surface water
Authors:Seitz Wolfram  Weber Walter H  Jiang Jia-Qian  Lloyd Barry J  Maier Matthias  Maier Dietrich  Schulz Wolfgang
Institution:Zweckverband Landeswasserversorgung, Betriebs- und Forschungslaboratorium, Am Spitzigen Berg 1, D-89129 Langenau, Germany.
Abstract:A monitoring programme was carried out in order to determine iodinated X-ray contrast media (ICM) in the River Danube and to investigate the raw water quality for drinking water production at Langenau waterworks. The study revealed that the maximum concentrations of ICM (over 500 ng l(-1) for diatrizoic acid and iopamidol) were found in 2h-composite samples taken from the downstream of the Ulm/Neu-Ulm metropolitan area. By means of a concentration profile over one month the highest ICM concentrations were observed on weekdays. The extended data evaluation with principal component analysis shows that the upstream and downstream samples had different pattern of variations in ICM concentration and also demonstrates a clear change in ICM composition by the discharge of municipal wastewater. In addition to load profiles of ICM, time-dependent plots of principal component 1 exhibited peaks, indicating a short-term discharge of ICM between the two sampling sites. In conclusion, a point source for ICM contamination between the sampling sites in Ulm upstream and Leipheim downstream seems to be the reasonable explanation for peak ICM concentrations. Due to the observed high variations of ICM concentrations in river, the evaluation of natural waters by means of a single analysis is not representative.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号