首页 | 本学科首页   官方微博 | 高级检索  
     检索      

双柱双ECD检测器-气相色谱法测定水中的灭蚁灵
作者姓名:杨素娜
作者单位:上海市嘉定区环境监测站;
摘    要:采用液液萃法取提取水中的灭蚁灵,经浓硫酸净化,用双柱双ECD检测器-气相色谱法进行测定。当取样体积为100ml时,ECD1(色谱柱DB-35ms)和ECD2(色谱柱HP-5)的检出限分别为0.051μg/L和0.038μg/L,六组水样加标回收率为81.6%和78.4%,相对标准偏差3.74%和2.32%。该方法一次进样可得到两组数据来进行灭蚁灵的定性和定量分析,排除了假阳性产生的可能性,因此定性更准确、定量更精确。

关 键 词:双柱双检测器  气相色谱法  水质  灭蚁灵

Determination of Mirex in Water with Double Column Double ECD Detctor - Gas Chromatography
Authors:YangSuna
Institution:YangSuna( Environment Monitoring Station of JiaDing District ShangHai City Shanghai 201822)
Abstract:Mirex in water was extracted by liquid - liquid extraction, purified through sulfuric acid and ana- lyzed with Double Column Double ECD - Gas Chromatography. The detection limits of ECD1 ( capillary col- umn DB-35ms) and ECD2 (capillary column HP-5) were respectively 0. 051μg/L and 0. 0381xg/L at 100ml sample. The recoveries of six matrix samples were 81.7% and 78.3%, RSDs were 3.74% and 2.32% In this method, two group data were obtained through one injetction, which could rule out the possibility of false positive results, and thus qualitative analysis could be more accurate and precise.
Keywords:Double Column Double ECD Gas Chromatography Water quality Mirex
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号