Comparison of membrane fouling in ultrafiltration of down-flow and up-flow biological activated carbon effluents
Authors:Lu Ao  Wenjun Liu  Yang Qiao  Cuiping Li  Xiaomao Wang
Institution:1. Department of Military Installation, Army Logistics University of PLA, Chongqing 401331, China2. School of Environment, Tsinghua University, Beijing 100084, China3. Urban Planning & Design Institute of Shenzhen, Shenzhen 518028, China
Abstract: The UF membrane fouling by down- and up-flow BAC effluents were compared. Up-flow BAC effluent fouled the membrane faster than down-flow BAC effluent. The combined effects dominated irreversible fouling. The extent of fouling exacerbated by inorganic particles was higher. The TMP, permeate flux, and normalized membrane flux during 21 days of UF of DBAC and UBAC effluents. Fouling during ultrafiltration of down- and up-flow biological activated carbon effluents was investigated to determine the roles of polysaccharides, proteins, and inorganic particles in ultrafiltration membrane fouling. During ultrafiltration of down- flow biological activated carbon effluent, the trans-membrane pressure was≤26 kPa and the permeate flux was steady at 46.7 L?m2?h1. However, during ultrafiltration of up-flow biological activated carbon effluent, the highest trans-membrane pressure was almost 40 kPa and the permeate flux continuously decreased to 30 L?m2?h1. At the end of the filtration period, the normalized membrane fluxes were 0.88 and 0.62 for down- and up-flow biological activated carbon effluents, respectively. The membrane removed the turbidity and polysaccharides content by 47.4% and 30.2% in down- flow biological activated effluent and 82.5% and 22.4% in up-flow biological activated carbon effluent, respectively, but retained few proteins. The retention of polysaccharides was higher on the membrane that filtered the down- flow biological activated effluent compared with that on the membrane that filtered the up-flow biological activated carbon effluent. The polysaccharides on the membranes fouled by up-flow biological activated carbon and down- flow biological activated effluents were spread continuously and clustered, respectively. These demonstrated that the up-flow biological activated carbon effluent fouled the membrane faster. Membrane fouling was associated with a portion of the polysaccharides (not the proteins) and inorganic particles in the feed water. When there was little difference in the polysaccharide concentrations between the feed waters, the fouling extent was exacerbated more by inorganic particles than by polysaccharides.
Keywords:Ultrafiltration  Membrane fouling  Down-flow biological activated carbon  Up-flow biological activated carbon  Particles  Polysaccharide  
本文献已被 SpringerLink 等数据库收录!
点击此处可从《Frontiers of Environmental Science & Engineering》浏览原始摘要信息
点击此处可从《Frontiers of Environmental Science & Engineering》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号