首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Self-registration methods for increasing membrane utilization within compression-sealed microchannel hemodialysers
Institution:1. School of Mechanical and Mining Engineering, The University of Queensland, Queensland, Australia;2. Centre for Advanced Research on Energy (CARe), Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka, Malaysia;1. Laboratoire Roberval, Université de Technologie de Compiègne, 60205 Compiègne, France;2. IRTES-LERMPS, Université de Technologie de Belfort Montbéliard, 90100 Belfort, France;3. CURAL-REGAL, Université du Québec à Chicoutimi, Saguenay, QC, Canada;1. School of Mechanical and Building Sciences, VIT University, Vellore 632 014, India;2. Defence Metallurgical and Research Laboratory, Hyderabad, India;1. State Key Laboratory of Hydraulic Engineering Simulation and Safety, Tianjin University, Tianjin 300072, PR China;2. Beijing Key Laboratory of Water Resources and Environmental Engineering, China University of Geosciences, Beijing 100083, PR China;3. Research Institute of Safety and Environment Technology, China National Petroleum Corporation, Beijing 102206, PR China;4. Department of Civil and Architectural Engineering, University of Wyoming, Laramie, WY 82071, USA;5. Advanced Environmental Technologies LLC., Fort Collins, CO 80525, USA;1. School of Mechanical & Building Sciences, VIT University, Vellore, India;2. Hindustan Aeronautics Limited, Bengaluru, India
Abstract:More than 1.2 million people worldwide require regular hemodialysis therapy to treat end stage renal failure. Current hemodialysis systems are too expensive to support at-home hemodialysis where more frequent and longer duration treatment can lead to better patient outcomes. The key cost driver for hemodialysers is the cost of the hemodialysis membrane. Microchannel hemodialysers are smaller providing the potential to use significantly less membrane. Prior work has demonstrated the use of sealing bosses to form compression seals in microchannel hemodialysers. In this paper, estimates show that the percentage of the membrane utilized for mass transfer is highly dependent on the design and registration accuracy of adjacent blood and dialysate laminae. Efforts here focus on the development of a self-registration method to align polycarbonate laminae compatible with compression sealing schemes for membrane separation applications. Self-nesting registration methods were demonstrated with average registration accuracies of 11.4 ± 7.2 μm measured over a 50 mm scale. Analysis shows that the registration accuracy is constrained by tolerances in the embossing process. A dialysis test article was produced using the self-nesting registration method showing a measured average one-dimensional misregistration of 18.5 μm allowing a potential 41.4% of the membrane to be utilized for mass transfer when considering both microchannel and header regions. Mass transfer results provide evidence of a twofold to threefold increase in membrane utilization over other designs in the existing literature.
Keywords:Microchannel  Hemodialysis  Self-registration  Compression sealing  Membrane
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号