首页 | 本学科首页   官方微博 | 高级检索  
     

浸入式短流程超滤膜生产工艺过程膜污染的形成与控制
引用本文:范青如,肖萍,肖峰,乔春光,秦潼,王东升. 浸入式短流程超滤膜生产工艺过程膜污染的形成与控制[J]. 环境科学, 2011, 32(5): 1351-1356
作者姓名:范青如  肖萍  肖峰  乔春光  秦潼  王东升
作者单位:1. 江苏高朗环境技术有限公司,南通,226007
2. 中国科学院生态环境研究中心饮用水科学与工程中心,北京,100085
3. 南通市自来水公司,南通,226007
基金项目:国家自然科学基金青年科学基金项目(51008293,50908224)
摘    要:
以江苏芦泾水厂膜技术改造工程为对象,从水质、膜工艺特征结合生产运行过程以及污染膜的清洗进行了分析,目的是了解膜污染的组分构成,评价不同清洗剂的清洗效果,获取较优的清洗顺序.结果表明,原水以憎水酸(HOA)和亲水组分(HIM)为主体,质量分数各占40.34%和28.48%.溶解性有机物(DOM)则以芳香性蛋白质Ⅱ类物质为...

关 键 词:超滤膜  膜污染  DOM表征  有机物  膜清洗
收稿时间:2010-10-05
修稿时间:2010-12-13

Membrane Fouling Mechanism and Control Strategy for the Pilot-Scale Submerged PVC-UF Membrane Process
FAN Qing-ru,XIAO Ping,XIAO Feng,QIAO Chun-guang,QIN Tong and WANG Dong-sheng. Membrane Fouling Mechanism and Control Strategy for the Pilot-Scale Submerged PVC-UF Membrane Process[J]. Chinese Journal of Environmental Science, 2011, 32(5): 1351-1356
Authors:FAN Qing-ru  XIAO Ping  XIAO Feng  QIAO Chun-guang  QIN Tong  WANG Dong-sheng
Affiliation:Go Long Environmental Co. Ltd., Nantong 226007, China. golongfqr@163.com
Abstract:
In this paper, Lujing water supply plant in Jiangsu was selected to carry out the investigation in order to understand the constitutes of the membrane fouling, comment on the membrane cleaning methods and obtain the proper cleaning sequences. In the experiments, water quality of the raw water was measured; membrane characteristics of the plant and membrane cleaning methods were thoroughly analyzed. The results indicated that the hydrophobic acids (HOA) and hydrophilic matters (HIM) are the major components in the raw water, 40.34% and 28.48% respectively in mass fraction. EEM's results also demonstrated that aromatic protein II are the main constitutes in the DOMs. In addition, the turbidity can reach around 0.1 NTU and the DOM can be removed partially by the PVC-UF membrane process during the water production. The constitutes of those emulations demonstrated that inorganic ions and NOM were both contributed to the membrane fouling. Ca and Si were the major inorganic contributors; aromatic protein II, SMP and fulvic acid were the major organic ones. According to SEM observation the sequence of the membrane cleaning should be HCl first, then NaOH.
Keywords:ultrafiltration membrane  membrane fouling  dissolved organic matters(DOM) characterization  organic matter  membrane cleaning
本文献已被 万方数据 PubMed 等数据库收录!
点击此处可从《环境科学》浏览原始摘要信息
点击此处可从《环境科学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号