首页 | 本学科首页   官方微博 | 高级检索  
     


PCDDs and PCDFs in sewage sludges from two wastewater treatment plants in Beijing, China
Authors:Li Xuemei  Ke Zhenshan  Dong Jizhen
Affiliation:Analysis and Measurement Center of Beijing Municipal Drainage Corporation, Beijing 100124, China
Abstract:The levels of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) were analyzed by an isotope-dilution high-resolution mass spectrometric in 16 sewage sludges, sampled from 2004 to 2009, from two municipal wastewater treatment plants (WWTPs) in Beijing. Total toxicity equivalent (TEQ) values were evaluated using the toxicity equivalent factors proposed by International for PCDD/Fs. The I-TEQs for these sewage sludges were from 0.97 to 15.0 pg g−1 dry weight (dw) with a mean value 4.43 pg g−1 dw, indicating that all I-TEQs were below Chinese legislation limit value regulated for agricultural use in soils.The results from limited samples (16 samples) showed that the levels of PCDD/Fs might be correlated with the sludge age. Meanwhile, the temporal trends of PCD/Fs suggested that the I-TEQs may correlate with rainfall in the present study.
Keywords:Dioxin   Furan   Wastewater treatment plant   Sewage sludge   Distribution
本文献已被 ScienceDirect PubMed 等数据库收录!