Estimation of the environmental risk posed by landfills using chemical, microbiological and ecotoxicological testing of leachates |
| |
Authors: | Matejczyk Marek Płaza Grażyna A Nałęcz-Jawecki Grzegorz Ulfig Krzysztof Markowska-Szczupak Agata |
| |
Affiliation: | a Waste Department, Institute for Ecology of Industrial Areas, 6 Kossutha, 40-844 Katowice, Poland b Department of Environmental Microbiology, Institute for Ecology of Industrial Areas, 6 Kossutha, 40-844 Katowice, Poland c Department of Environmental Health Sciences, Medical University of Warsaw, 1 Banacha, 02-097 Warsaw, Poland d Polymer Institute Division of Biomaterials and Microbiological Technologies, West Pomeranian University of Technology, 10 Pulaskiego, 70-322 Szczecin, Poland e Institute of Chemical and Environment Engineering, West Pomeranian University of Technology, 10 Pulaskiego, 70-322 Szczecin, Poland |
| |
Abstract: | The leachates from 22 municipal solid waste (MSW) landfill sites in Southern Poland were characterized by evaluation of chemical, microbiological and ecotoxicological parameters. Chemical analyses were mainly focused on the identification of the priority hazardous substances according to Directive on Priority Substances, 2008/105/EC (a daughter directive of the WFD) in leachates. As showed, only five substances (Cd, Hg, hexachlorobutadiene, pentachlorobenzene and PAHs) were detected in the leachates. The compounds tested were absent or present at very low concentrations. Among them, only PAHs were found in all samples in the range from 0.057 to 77.2 μg L−1. The leachates were contaminated with bacteria, including aerobic, psychrophilic and mesophilic bacteria, coliform and fecal coliforms, and spore-forming-bacteria, including Clostridium perfringens, and with filamentous fungi. From the analysis of specific microorganism groups (indicators of environmental pollution by pathogenic or opportunistic pathogenic organisms) it can be concluded that the landfill leachates showed sanitary and epidemiological hazard. In the ecotoxicological study, a battery of tests comprised of 5 bioassays, i.e. Microtox®, Spirotox, Rotoxkit F™, Thamnotoxkit F™ and Daphtoxkit F™ magna was applied. The leachate samples were classified as toxic in 13.6%, highly toxic in 54.6% and very highly toxic in 31.8%. The Spirotox test was the most sensitive bioassay used. The percentage of class weight score was very high - above 60%; these samples could definitely be considered seriously hazardous and acutely toxic to the fauna and microflora.No correlations were found between the toxicity values and chemical parameters. The toxicity of leachate samples cannot be explained by low levels of the priority pollutants. It seems that other kinds of xenobiotics present in the samples at subacute levels gave the high aggregate toxic effect.The chemical, ecotoxicological and microbiological parameters of the landfill leachates should be analyzed together to assess the environmental risk posed by landfill emissions. |
| |
Keywords: | Leachates Priority hazardous substances Bioassays Microbial indicators Risk assessment |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|