冬季条件下曝气生物滤池处理模拟灰水的应用研究
引用本文:陈广银,陈洪斌,何群彪,张小龙,钱玮玮.冬季条件下曝气生物滤池处理模拟灰水的应用研究[J].环境科学与管理,2008,33(11):55-58.
作者姓名:陈广银  陈洪斌  何群彪  张小龙  钱玮玮
作者单位:[1]同济大学国家污染控制工程中心,上海200092; [2]同济大学生命科学与工程学院,上海200092; [3]颍上县环境保护局,安徽颍上236200
基金项目:国家科技部中德合作项目
摘    要:文章采用陶粒滤料为载体,研究了在冬季低温条件下化学混凝-曝气生物滤池工艺对模拟灰水的中试研究。实验结果表明,在冬季水温为3℃-15℃的条件下,初沉处理大大减轻了后续曝气生物滤池的运行负荷的同时也提高了整个工艺的搞冲击能力。当曝气生物滤池水力负荷为3.8m/h时,COD、LAS的去除效率分别在70%、80%以上。NH4-N去除效率受LAS、COD、温度影响较大,整个工况去除效率在15%~75%。NH4-N的去除效率随着COD负荷的增加,其去除效率受到严重的影响。COD的去除负荷率为2.85kg/(m^3滤料·d)升高到5.04kg/(m^3滤料·d)时,NH4-N的去除率则由61%-77%,下降到26%~41%,说明了异养微生物的生长严重抑制了硝化亚硝化细菌的生长。

关 键 词:曝气生物滤池  低温  模拟灰水  COD负荷

An Study of BAF on the Treatment on the Simulated Greywater in Winter
Chen Guangyin,Chen Hongbin,He Qunbiao,Zhang Xiaolong,Qian Weiwei.An Study of BAF on the Treatment on the Simulated Greywater in Winter[J].Environmental Science and Management,2008,33(11):55-58.
Authors:Chen Guangyin  Chen Hongbin  He Qunbiao  Zhang Xiaolong  Qian Weiwei
Institution:Chen Guangyin,Chen Hongbin, He Qunbiao, Zhang Xiaolong, Qian Weiwei( 1. National Engineering Research Center for Urban Pollution Control, Tongji University, Shanghai 200092, China ; 2. School of Life Sciences and Technology, Shanghai 200092, China; 3. Yingshang County EPA, Yingshang 236200, China)
Abstract:The down- flow biological aerated filter with light pottery media had been adopted on the treatment of domestic simulated greywater during the winter. The test temperature was 3℃ - 15℃. In order to compare the efficient of the treatment , The coagulating sedimentation pretreatment was proposed with PAC dosage is 40 mg/L, 20 mg/L,0 mg/L. The running result showed that coagulating sedimentation pretreatment greatly lightened the loading rate of the biological aerated filter. The removal rates of the COD ,LAS were 70% ,80% when the hydraulics loading rate is 3.8 m/h. NH4 - N removal efficient was 15% - 75% which was badly influenced by the temperature and concentrations of the LAS,COD . The removal rate of the NH4 - N was 61% - 77% ,26% -41% respectively with the COD loading rate increased from 2. 85 kg/( m^3 filters · d) to 5.04 kg( m^3 filters · d), which indicated hetermicroorganism had an adverse influence on nitrobacteria's growth.
Keywords:biological aerated filter(BAF)  low temperature  simulate greywater  COD loading rates
本文献已被 维普 万方数据 等数据库收录!