首页 | 本学科首页   官方微博 | 高级检索  
     


An evaluation of measurement methods for organic, elemental and black carbon in ambient air monitoring sites
Authors:Paul Quincey   David Butterfield   David Green   Mhairi Coyle  J. Neil Cape
Affiliation:aAnalytical Science Division, National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, UK;bEnvironmental Research Group, King's College London, Franklin-Wilkins Building, 150 Stamford Street, London SE1 9NN, UK;cCentre for Ecology & Hydrology, Bush Estate, Penicuik, Midlothian EH26 0QB, UK
Abstract:The carbonaceous components of Particulate Matter samples form a substantial fraction of their total mass, but their quantification depends strongly on the instruments and methods used. United Kingdom monitoring networks have provided many relevant data sets that are already in the public domain. Specifically, hourly organic carbon (OC) and elemental carbon (EC) were determined at four sites between 2003 and 2007 using Rupprecht and Pattashnik (R & P) 5400 automatic instruments. Since 2007, daily OC/EC measurements have been made by manual thermo-optical analysis of filter samples using a Sunset Laboratory Carbon Aerosol Analysis instrument. In parallel, long term daily measurements of Black Smoke, a quantity directly linked to black carbon (measured by aethalometers) and indirectly related to elemental carbon, have been made at many sites. The measurement issues associated with these techniques are evaluated in the context of UK measurements, making use of several sets of parallel data, with the aim of aiding the interpretation of network results. From the results available, the main conclusions are that the R & P 5400 instruments greatly under-read EC and total carbon (TC = OC + EC) at kerbside sites, probably due to the fact that the smaller particles are not sampled by the instrument; the R & P 5400 instrument is inherently difficult to characterise, so that all quantitative results need to be treated with caution; both aethalometer and Black Smoke (converted to black carbon) measurements can show reasonable agreement with elemental carbon results; and manual thermo-optical OC/EC results may under-read EC (and hence over-read OC), whether either transmittance or reflectance is used for the pyrolysis correction, and this effect is significant at rural sites.
Keywords:Black Smoke   Black carbon   Organic carbon   Elemental carbon   Air quality   UK
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号