引用本文:王菊思,赵丽辉,贾智萍,王正兰,郭玥. 镍对厌氧消化过程的抑制作用研究[J]. 环境科学, 1993, 14(6): 5-7,42
作者姓名:王菊思  赵丽辉  贾智萍  王正兰  郭玥
作者单位:中国科学院生态环境研究中心,中国科学院生态环境研究中心,中国科学院生态环境研究中心,北京市太阳能研究所,北京市太阳能研究所 北京 100085,北京 100085,北京 100085,北京 100083,北京 100083
基金项目:国家“七五”科技攻关课题
摘    要:采用混合式厌氧反应器,以酒糟废水为基质,在相同条件的不同反应器中每日加入不同浓度的镍离子(以硝酸镍形式加入),研究不同浓度的镍离子对厌氧体系的抑制作用,以及体系中溶解态的镍离子含量与抑制程度的关系。结果表明,日加入镍量低于36.4mg/L时,对体系无影响;在40-60mg/L时,产生轻微的抑制;超过80mg/L时,对体系造成严重的抑制。当体系中溶解态镍离子浓度低于2.5mg/L时,体系不受影响。厌

关 键 词:镍 厌氧消化 抑制作用 废水处理
收稿时间:1993-07-20

Inhibition of Nickel to the Anaerobic Digestion
Wang Jusi. Inhibition of Nickel to the Anaerobic Digestion[J]. Chinese Journal of Environmental Science, 1993, 14(6): 5-7,42
Authors:Wang Jusi
Affiliation:Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085;Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085;Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085
Abstract:The inhibition of nickel ion to anaerobic digestion was described in this paper. Nickel ion was added at different concentrations in three experimental digesters. No inhibition effect on the anaerobic system was observed when daily addition of nickel to the digester was less than 36. 4 mg/L. When the daily addition of nickel was 40-60mg/L, or more than 80mg/ L, however, digestion system was inhibited significantly or seriously, respectively. Toxicity of nickel to anaerobic system was found to be dependent on the concentration of dissolved nickel ions in digester. The systemwas not affected when the concentration of dissolved nickel ion is less than 2. 5mg/ L. At the ratio of concentration of daily nickel addition to activated sludge (dry weight) being less than 0. 08(w/w), the digestion system would be normally running.
Keywords:nickel   anaerobic digestion   inhibition effect.